| Pulse-plethysmographic variables in hemodynamic assessment during mannitol infusion. | |
| | |
MedLine Citation:
|
PMID: 22318409 Owner: NLM Status: Publisher |
Abstract/OtherAbstract:
|
Plethysmographic signal using pulse oximetry may be used to assess fluid status of patients during surgery as it resembles arterial pressure waveform. This will avoid placement of invasive arterial lines. This study was designed to find out whether intravascular volume changes induced by mannitol bolus in neurosurgical patients are detected by variations in arterial pressure and plethysmographic waveforms and also to assess the strength of correlation between different variables derived from these two waveforms. The time difference between the onset of arterial and plethysmographic waveforms as means of significant hemodynamic changes was also evaluated. Forty one adult ASA I and II neurosurgical patients requiring mannitol infusion were recruited. Arterial line and plethysmographic probe were placed in the same limb. Digitized waveforms were collected before, at the end, and 15, 30 and 60 min after mannitol infusion. Using MATLAB, the following parameters were collected for three consecutive respiratory cycles,-systolic pressure variation (SPV), pulse pressure variation (PPV), plethysmographic peak variation (Pl-PV), plethysmographic amplitude variation (Pl-AV) and blood pressure-plethysmographic time lag (BP-Pleth time lag). Changes in above parameters over the study period were studied using repeated measure analysis of variance. Correlation between the parameters was analysed. SPV and Pl-PV showed significant increase at 15, 30 and 60 min compared to end of mannitol infusion (P < 0.01 for SPV; P < 0.05 for Pl-PV). PPV and Pl-AV showed significant increase only at 30 min (P < 0.05). The correlation between ∆SPV-∆Pl-PV, ∆PPV-∆Pl-AV and ∆SPV-∆BP-Pleth time lag were significant (r = 0.3; P < 0.01). SPV and time lag had no significant interaction. Pl-PV correlates well with SPV following mannitol infusion and can be used as an alternative to SPV. (BP-Pleth) time-lag promises to be an important parameter in assessing the state of peripheral vascular resistance and deserves further investigation. |
| | |
Authors:
|
M Radhakrishnan; K Mohanvelu; S Veena; G Sripathy; G S Umamaheswara Rao |
Related Documents
:
|
7270439 - Prediction of postoperative performance in aortic valve disease. 7236179 - Quantitative data on the afterload dependence of left ventricular dp/dtmax in isolated ... 18371489 - Noninvasively determined radial dp/dt is a predictor of mortality in patients with hear... 8110059 - Assisted circulation using cardiomyoplasty together with aortomyoplasty. 22495249 - Overtime work and blood pressure in normotensive japanese male workers. 22327709 - Bedside study of cerebral critical closing pressure in patients with severe traumatic b... 7240839 - Biodynamics of the cervical dilatation in human labor. 16936429 - Effects of pulse-synchronized massage with air cuffs on peripheral blood flow and auton... 935109 - Efferent arterioles in glomerular haemodynamics. |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2012-2-9 |
Journal Detail:
|
Title: Journal of clinical monitoring and computing Volume: - ISSN: 1573-2614 ISO Abbreviation: - Publication Date: 2012 Feb |
Date Detail:
|
Created Date: 2012-2-9 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 9806357 Medline TA: J Clin Monit Comput Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Affiliation:
|
Department of Neuroanaesthesia, National Institute of Mental Health and Neuro Sciences (NIMHANS), Bangalore, Karnataka, 560029, India. |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Decision to evacuate a hospital during an emergency: The safe way or the leader's way?
Next Document: Quasiclassical trajectory calculations of hydrogen absorption in the (NaAlH(4))(2)Ti system on a mod...