Pulse oximetry with the laryngeal mask airway.
MedLine Citation:
PMID:  10636319     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
This study evaluated the accuracy of pulse oximetry measured by a modified laryngeal mask airway (LMA). Ten anaesthetized patients (ASA I-II, aged 18-45) undergoing elective knee arthroscopies (mean-duration 40 min) were studied. A transmission pulse oximeter probe/sound OHMEDA was attached on the back of LMA (sizes 4 and 5) in an area in contact with the floor of the laryngeal part of the pharynx. Pharyngeal pulse oximetry as well as LMA cuff pressure were monitored and recorded every 5 min from the time of insertion (T0) to removal (T8) and were compared to simultaneous finger pulse oximeter readings. At T2 the cuff was over-inflated to obtain a 100 cm H2O intracuff pressure. At T3 the cuff pressure was decreased at 60 cm H2O. Pharyngeal pulse oximetry correlated with finger pulse oximetry throughout the study and was not effected by over-inflation of the LMA. This modification of the LMA provides an accurate method of measuring pulse oximetry which may be of use in a variety of circumstances.
Authors:
F Agrò; M Carassiti; R Cataldo; S Gherardi; G Barzoi
Related Documents :
2513219 - Functional similarities in the mechanical design of the aorta in lower vertebrates and ...
16901849 - Pulse-wave morphology and pulse-wave velocity in healthy human volunteers: examination ...
10468359 - Viscoelasticity modulates resonance in the terminal aortic circulation.
20000949 - Ambient pressure sensitivity of microbubbles investigated through a parameter study.
3089029 - Pulse-wave model of brachial arterial pressure modulation in aging and hypertension.
1788839 - Hemodynamic assessment of radial-arterial pressure-wave contours in children.
14659949 - Real-time-monitored decrease of trichlorophenol as a dioxin surrogate in flue gas using...
12569269 - Atorvastatin causes depressor and sympatho-inhibitory effects with upregulation of nitr...
8712329 - The effect of increasing the dose of buprenorphine on the haemodynamic response associa...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Resuscitation     Volume:  43     ISSN:  0300-9572     ISO Abbreviation:  Resuscitation     Publication Date:  1999 Dec 
Date Detail:
Created Date:  2000-02-03     Completed Date:  2000-02-03     Revised Date:  2009-08-25    
Medline Journal Info:
Nlm Unique ID:  0332173     Medline TA:  Resuscitation     Country:  IRELAND    
Other Details:
Languages:  eng     Pagination:  65-7     Citation Subset:  IM    
Affiliation:
Departement of Anaesthesia, University School of Medicine Campus Bio-Medico, Rome, Italy. f.agro@unicampus.it
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Female
Humans
Laryngeal Masks*
Male
Oximetry*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The place of general practitioners in the management of out-of-hospital cardiopulmonary resuscitatio...
Next Document:  Sex differences in adolescent suicides in Norway, 1990-1992.