Document Detail


Pseudoenhancement of simple renal cysts: a comparison of single and multidetector helical CT.
MedLine Citation:
PMID:  11801909     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: The purpose of this work was to compare the extent of pseudoenhancement (artifactual increase in measured attenuation of a simple cyst after contrast medium administration) in a phantom model on single detector and multidetector helical CT scanners. METHOD: The phantom consisted of four water-filled spheres varying in size from 8 to 28 mm, suspended in an aqueous contrast medium bath. Iodine concentration in the bath was varied: 0, 6, 12, and 24 mg/ml corresponding to attenuation values of 0, +108, +180, and +300 HU. The phantom was scanned on single detector and multidetector helical CT scanners during the same session. Collimation (1, 3, and 5 mm) and pitch (1 and 1.5:1, single detector; 3:1 and 6:1, multidetector) were varied at each concentration. All scans were performed at 140 kVp and 170 mA. The region of interest was measured at the center of each sphere. The effects were analyzed using a linear regression model. RESULTS: The degree of pseudoenhancement was more pronounced with increasing iodine concentration, decreasing cyst size, and wider collimation (all p = 0.0001). Pseudoenhancement was also more marked on the multidetector than the single detector scanner (p = 0.0001). At physiological levels of renal enhancement, the average pseudoenhancement was +18 HU for the single detector versus +23 HU for the multidetector scanner. Variation in pitch had no effect. CONCLUSION: Pseudoenhancement is greater on a multidetector than a single detector helical CT scanner and may exceed 20 HU at physiological levels of renal enhancement.
Authors:
Joan P Heneghan; Audrey L Spielmann; Douglas H Sheafor; Mark A Kliewer; David M DeLong; Rendon C Nelson
Related Documents :
11455749 - Visual survey of cancer dissemination: classic patterns on helical ct of the neck and t...
1566679 - Assessment of the thoracic aorta by spiral ct.
1457539 - Three-dimensional display of hepatic venous anatomy generated from spiral computed tomo...
7567259 - Reduced need for sedation in patients undergoing helical ct of the chest and abdomen.
17705009 - Improvement in image quality of noncontrast head images in multidetector-row ct by volu...
15789609 - Comparison of helical and cine acquisitions for 4d-ct imaging with multislice ct.
20164559 - Diagnostic utility of novel mri-based biomarkers for alzheimer's disease: diffusion ten...
2006279 - Senile dementia and healthy aging: a longitudinal ct study.
19617599 - Evaluation of radiation doses from mdct-imaging in otolaryngology.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Journal of computer assisted tomography     Volume:  26     ISSN:  0363-8715     ISO Abbreviation:  J Comput Assist Tomogr     Publication Date:    2002 Jan-Feb
Date Detail:
Created Date:  2002-01-21     Completed Date:  2002-02-15     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  7703942     Medline TA:  J Comput Assist Tomogr     Country:  United States    
Other Details:
Languages:  eng     Pagination:  90-4     Citation Subset:  IM    
Affiliation:
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA. heneg002@mc.duke.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Contrast Media
Humans
Image Enhancement
Kidney Diseases, Cystic / radiography*
Phantoms, Imaging
Tomography, X-Ray Computed / methods*
Chemical
Reg. No./Substance:
0/Contrast Media

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Right-sided colonic diverticulitis: CT findings.
Next Document:  Radiologic findings of gastrointestinal tract involvement in hepatocellular carcinoma.