Document Detail


Prostate gland motion and deformation caused by needle placement during brachytherapy.
MedLine Citation:
PMID:  15090279     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: To determine the extent of edge and gland position changes caused by needle insertion in patients undergoing prostate brachytherapy. METHODS AND MATERIALS: Nineteen patients with T1-T3 prostate cancer were implanted with the real-time method by using a two-phase peripheral loading technique. Serial contours of the prostate at 5-mm intervals were acquired by the dose-planning system. All of the peripheral needles were then placed and spaced 5-10 mm apart by using the largest transverse ultrasound image as the reference plane. The position of the probe was relocated at the zero plane, and the difference between the preneedle and postneedle zero plane was recorded as the difference in the z axis. Axial ultrasound images were again acquired. The second set of captured images, which matched in number the first set, was contoured over the previously contoured preneedle images. Prostate gland deformation and displacement were determined by comparing the preneedle contoured image with the images captured after needle placement. Deformation was determined by calculating the differences between the edges of the gland as measured at the major axis of the gland (x and y planes). Displacement was determined by measuring the differences between the center positions of the two contoured structures. Deformation and displacement were determined on each acquired 5-mm image. Differences were compared by student's t test. RESULTS: The mean preneedle prostate volume was 47 ml (range, 21.5-68.7 ml), compared with 48.1 ml (range, 19.4-80.3 ml; p = 0.228) after peripheral needle placement. A median of 16 (range, 12-19) peripheral needles were placed. The median change in the base position of the prostate was 1.5 cm (range of 0 to 3.0 cm; p = 0.0034). The mean x and y deformation was 6.8 mm (median, 7.9 mm; range, 4.3-8.1 mm) and 3.6 mm (median, 3.3 mm; range, 1.0-5.5 mm), respectively. The greatest deformation for any individual slice for x was 21.6 mm and for y was 15.3 mm. The mean number of slices that were found with a >2-, 5-, and 10-mm deformation in the x axis was 7 (range, 3-10), 4 (range, 1-3), and 1 (range, 0-4), respectively. Similar deformation in the y axis was found in 6 (range, 3-10), 2.5 (range, 0-6), and 0.3 (range, 0-2) slices. The mean x and y displacement was 1.9 mm (median, 1.8 mm; range, 0.3-6.6 mm) and 2.8 mm (median, 1.9 mm; range, 2-5.8 mm). The greatest displacement for any individual slice for x was 7 mm and for y was 10 mm. The mean number of slices with a displacement >2, 5, and 10 mm in the x axis was 5 (range, 1-10), 0.8 (range, 0-5), and 0, respectively. Similar displacement in the y axis was found in 5 (range, 0-9), 1.7 (range, 0-7), and 0 slices, respectively. CONCLUSIONS: Placing most needles in the periphery results in a minimal prostate volume increase, suggesting little need to overplan the implant when this method is used. However, significant edge and gland position changes caused by the needle insertion did occur. These changes may explain some of the difficulty in reproducing the preplan and should be taken into consideration for all types of prostate brachytherapy planning.
Authors:
Nelson N Stone; Jiten Roy; Suzanne Hong; Yeh-Chi Lo; Richard G Stock
Related Documents :
24493909 - Contact cmos imaging of gaseous oxygen sensor array.
19735879 - Measurement of interfraction variations in position and size of target volumes in stere...
12535869 - Po(2) measurements by phosphorescence quenching: characteristics and applications of an...
20846849 - The effect of registration surrogate and patient factors on the interobserver variabili...
15083669 - Integrated radiotherapy imaging system (iris): design considerations of tumour tracking...
23389009 - Numerical compensation of system polarization mode dispersion in polarization-sensitive...
19118599 - Imaging of phosphatidylcholines in the adult rat brain using maldi-tof ms.
12201409 - Effect of radiographic techniques (kvp and mas) on image quality and patient doses in d...
10734489 - Computer analysis of video and ultrasonographic images for evaluation of bull testes.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Brachytherapy     Volume:  1     ISSN:  1538-4721     ISO Abbreviation:  Brachytherapy     Publication Date:  2002  
Date Detail:
Created Date:  2004-04-19     Completed Date:  2004-05-05     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  101137600     Medline TA:  Brachytherapy     Country:  United States    
Other Details:
Languages:  eng     Pagination:  154-60     Citation Subset:  IM    
Affiliation:
Department of Urology, Mount Sinai School of Medicine, New York, NY, USA. nproseed@aol.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Brachytherapy / adverse effects*,  methods*
Humans
Male
Needles*
Prostate / pathology*
Prostatic Neoplasms / radiotherapy

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Pulsed-dose rate brachytherapy with concomitant chemotherapy and interstitial hyperthermia in patien...
Next Document:  Radioactive gold grain implants in recurrent and locally advanced head-and-neck cancers.