Prolonged hemodynamic stability during arteriovenous carbon dioxide removal for severe respiratory failure.
MedLine Citation:
PMID:  9434706     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVE: The effects of prolonged arteriovenous carbon dioxide removal on hemodynamics during severe respiratory failure were evaluated in adult sheep with severe smoke inhalation injury. METHODS: Adult female sheep (n = 6,33.8 +/- 5.2 kg) were subjected to intratracheal cotton severe smoke insufflation to a mean carboxyhemoglobin level of 83% +/- 3%. Twenty-four hours after injury, a low-resistance 2.5 m2 membrane oxygenator was placed in a carotid-to-jugular pumpless arteriovenous shunt at unrestricted flow to allow complete carbon dioxide removal and reductions in ventilator support. Animals remained conscious, and heart rate, cardiac output, mean arterial pressure, and pulmonary arterial pressure were measured at baseline, after injury, and daily during support with the arteriovenous carbon dioxide removal circuit for 7 days. RESULTS: All animals survived the study period. Carbon dioxide removal ranged from 99.7 +/- 13.7 to 152.2 +/- 16.2 ml/min, and five (83%) of the six animals were successfully weaned from the ventilator before day 7. During full support with the arteriovenous carbon dioxide removal circuit, shunt flow ranged from 1.24 +/- 0.06 to 1.43 +/- 0.08 L/min and accounted for 20.1% +/- 1.4% to 25.9% +/- 2.4% of cardiac output. No statistically significant changes in heart rate, cardiac output, mean arterial pressure, or pulmonary artery pressure were demonstrated over the study course despite the extracorporeal shunt flow. CONCLUSIONS: Arteriovenous carbon dioxide removal as a simplified means of extracorporeal gas exchange support is relatively safe without adverse hemodynamic effects or complications.
Authors:
R L Brunston; W Tao; A Bidani; S K Alpard; D L Traber; J B Zwischenberger
Related Documents :
22316906 - The use of thermal manikin to evaluate interface pressure distribution.
11220716 - Safety and accuracy of bedside carbon dioxide cavography for insertion of inferior vena...
3086046 - Hypnosis effect on carbon dioxide chemosensitivity.
10228116 - Effects of inhaled carbon dioxide and oxygen on cheyne-stokes respiration in patients w...
25399016 - Optimal number of days for home blood pressure measurement.
3753076 - Prevention of reperfusion injury of the ischemic spinal cord: use of recombinant supero...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  The Journal of thoracic and cardiovascular surgery     Volume:  114     ISSN:  0022-5223     ISO Abbreviation:  J. Thorac. Cardiovasc. Surg.     Publication Date:  1997 Dec 
Date Detail:
Created Date:  1998-02-12     Completed Date:  1998-02-12     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  0376343     Medline TA:  J Thorac Cardiovasc Surg     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1107-14     Citation Subset:  AIM; IM    
Affiliation:
Department of Surgery, University of Texas Medical Branch, Galveston 77550-0528, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Animals
Carbon Dioxide / blood*
Disease Models, Animal
Extracorporeal Membrane Oxygenation* / methods
Female
Hemodynamics / physiology*
Oxygenators, Membrane
Respiration, Artificial
Respiratory Distress Syndrome, Adult / physiopathology,  therapy*
Smoke Inhalation Injury / physiopathology,  therapy*
Time Factors
Chemical
Reg. No./Substance:
124-38-9/Carbon Dioxide

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  New method for monitoring the functional state of a dynamic cardiomyoplasty.
Next Document:  Hormone regulation of bovine leukemia virus via the long terminal repeat.