Document Detail


Problems with assays based on fibrin clot formation principle: analysis of multilaboratory data.
MedLine Citation:
PMID:  9834619     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
In order to investigate the inter-laboratory differences of coagulation assays, three different control plasmas were distributed for coagulation assays to 162 institutes. Three types of coagulation tests, that is, prothrombin time (PT), activated partial thromboplastin time (APTT), and fibrinogen (Fbg) assay were carried out by routine methods in each institute. In our laboratory, the Fbg concentrations were measured in two different plasmas using one instrument and nine reagents, and the Fbg concentrations were measured in ten control plasmas using three instruments and one reagent. Results were obtained as follows: (1) The coefficient of variance (CV) for control plasma with the highest value was significant in the PT assay and APTT assay. (2) Inter and intra-institute differences in PT and APTT assays were observed when the reagent or the instrument used was changed. (3) Inter and intra-institute differences in PT and APTT assays were also observed when both the reagent and the instrument were changed. (4) Inter and intra-institute differences in the PT and APTT assays were observed between the manual and the mechanical methods. (5) The CVs for the Fbg assays were the largest in the plasma at the lowest concentration of the three plasmas. (6) When control plasmas of three different Fbg concentrations were assayed, the number of the institutes which obtained a value greater than 3 standard deviations (SDs) was highest for the control plasma with the lowest concentrations of Fbg, and some of the instruments were not able to measure such a low Fbg concentration. (7) When the fibrinogen concentration was measured in various kinds of commercially-available control plasmas with a calibrated instrument, the values determined were different from the assigned ones and varied significantly from instrument to instrument. From the results, we concluded that standardization of the quality of control plasma, and its value assignment to the plasma should be established as soon as possible, and that a reliable standard fibrinogen assay should be developed.
Authors:
N Hirai; N Tatsumi; M Hino; T Yamane; K Ohta
Related Documents :
15563879 - Determination of apolipoprotein b-48 in serum by a sandwich elisa.
520279 - A sensitive, convenient radioimmunoassay procedure which demonstrates that serum htsh i...
16875889 - A simple and rapid determination of biapenem in plasma by high-performance liquid chrom...
7695259 - Application of a radioimmunoassay for determination of levels of zalcitabine (ddc) in h...
417169 - Improved glc determination of plasma nitroglycerin concentrations.
7055909 - Colorimetry of serum acetaminophen (paracetamol) in uremia.
23105539 - Seminal plasma levels of 15-f2α-isoprostane, malondialdehyde and total homocysteine in...
7990099 - Polymorphisms in the gene encoding angiotensin 1-converting enzyme and relationship to ...
3713439 - Plasma parathyroid hormone during acute volume expansion in the rat.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Osaka city medical journal     Volume:  44     ISSN:  0030-6096     ISO Abbreviation:  Osaka City Med J     Publication Date:  1998 Jun 
Date Detail:
Created Date:  1998-12-29     Completed Date:  1998-12-29     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  0376413     Medline TA:  Osaka City Med J     Country:  JAPAN    
Other Details:
Languages:  eng     Pagination:  55-71     Citation Subset:  IM    
Affiliation:
Department of Clinical and Laboratory Medicine, Osaka City University Medical School, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Blood Coagulation / physiology*
Blood Coagulation Tests / standards
Fibrin / physiology*
Fibrinogen / analysis
Humans
Laboratories / standards
Partial Thromboplastin Time
Prothrombin Time
Chemical
Reg. No./Substance:
9001-31-4/Fibrin; 9001-32-5/Fibrinogen

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effects of endometrial stromal cells and peritoneal fluid on fertility associated with endometriosis...
Next Document:  Heat-sensitive liposomes containing cisplatin and localized hyperthermia in treatment of murine tumo...