Document Detail


Prevention of Caval Collapse During Venous Drainage for CPB.
MedLine Citation:
PMID:  23263336     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
A new plastic self-expanding Smartcanula (Smartcanula LLC, Lausanne, Switzerland) is designed for central insertion and prevention of caval collapse. The objective of our work is to assess the influence of the new design on atrial chatter. Caval collapse over the entire caval axis, right atrial, hepatic, renal vein, and iliac vein is realized in drainage tubes with holes at 5 cm distance intervals. Smartcanulas with various lengths (26 cm [= right atrial], 34 cm [= hepatic], 43 cm [= renal], and 53 cm [= iliac]) versus two-stage cannulas are compared. Pressure drop ([INCREMENT]P) is measured using Millar pressure-transducers. Flow rate (Q) is measured using an ultrasonic flow meter. Cannula resistance is defined as the [INCREMENT]P/Q ratio. Data display and recording are controlled using LabView virtual instruments. At an 88 cm height differential, Q values are 8.69 and 6.8 l/min, and [INCREMENT]P/Q ratios are 0.63 and 1.28 for the 26-cm Smartcanula and the reference cannula, respectively. The 34-cm Smartcanula showed 8.89 l/min and 0.6 [INCREMENT]P/Q ratio vs. 7.59 l/min and 0.9 for the control cannula (P < 0.05). The 43-cm and 53-cm Smartcanulas showed Q values of 9.04 and 8.81 l/min, respectively, and [INCREMENT]P/Q ratio of 0.6. The Smartcanula outperforms the two-stage cannula, and direct cannula insertion without guide wire is effective.
Authors:
Saad Abdel-Sayed; Julien Favre; Steven Taub; Ludwig-Karl von Segesser
Related Documents :
15321496 - Influence of maternal position during epidural labor analgesia.
25064966 - O-011 quantitative mra is correlated with intravascular pressures before and after ve...
22138666 - Arsenic exposure and hypertension: a systematic review.
1418206 - Intraarticular pressures in a gravity-fed arthroscopy fluid delivery system.
7778546 - Relation between electrocardiography and echocardiography for left ventricular mass in ...
7746166 - Importance of valves and lymphangion contractions in determining pressure gradients in ...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-12-19
Journal Detail:
Title:  ASAIO journal (American Society for Artificial Internal Organs : 1992)     Volume:  -     ISSN:  1538-943X     ISO Abbreviation:  ASAIO J.     Publication Date:  2012 Dec 
Date Detail:
Created Date:  2012-12-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9204109     Medline TA:  ASAIO J     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
From the *Department of Cardiovascular Surgery, University Hospital CHUV, Lausanne, Switzerland; and †Laboratory for Movement Analysis and Measurement, Swiss Federal Institute of Technology, Lausanne-Switzerland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Low Bearing Wear in Explanted HeartMate II Left Ventricular Assist Devices After Chronic Clinical Su...
Next Document:  Which Is the Better Option During Neonatal Cardiopulmonary Bypass: HTK Solution or Cold Blood Cardio...