Document Detail


Presternal peritoneal catheter.
MedLine Citation:
PMID:  12085389     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The swan neck presternal catheter is composed of 2 flexible (silicon rubber) tubes joined by a titanium connector at the time of implantation. The exit site is located in the parasternal area. The catheter located on the chest was designed to reduce the incidence of exit site infections compared to peritoneal dialysis catheters with abdominal exits. From August 1991 to September 30, 2001, 974 swan neck presternal catheters were implanted worldwide. At the university of Missouri, 150 of these catheters were implanted and followed for over 130 patient years. Presternal catheters tended to perform better than swan neck abdominal catheters regarding exit and tunnel infections, even though they were implanted in several patients in whom regular catheters with the exit on the abdomen would be difficult or impossible to implant. Two-year survival probability of presternal catheters was 0.95. Recurrent/refractory peritonitis was the only reason for catheter failure. The catheter is particularly useful in obese patients (body mass index >35), patients with ostomies, children with diapers and fecal incontinence, and patients who want to take baths without the risk of exit contamination. Many patients prefer presternal catheter because of better body image. Disadvantages of the presternal catheter are minimal. Compared with abdominal catheters, dialysis-solution flow is slightly slower because of the increased catheter length; however, slower flow is insignificant clinically. There is a possibility of catheter disconnection in the tunnel, but this complication is extremely rare in adults and easily corrected. Finally, the implantation technique is more challenging compared with that of single-piece, abdominal catheters.
Authors:
Zbylut J Twardowski
Related Documents :
7750289 - Serum norethindrone levels and menstrual pattern after the use of norethindrone implant...
6430639 - A two-year experience with norplant implants in assiut, egypt.
1979289 - Study of norplant implants in shanghai: three-year experience.
21789489 - Clostridium beijerinckii mutant with high inhibitor tolerance obtained by low-energy io...
3789199 - Micturition in rats: a chronic model for study of bladder function and effect of anesth...
11403669 - The heartmate iii: design and in vivo studies of a maglev centrifugal left ventricular ...
19899969 - Expanded polytetrafluoroethylene membrane alters tissue response to implanted ahmed gla...
7993609 - Shear bond strength of composite to enamel and dentin using scotchbond multi-purpose.
20491839 - Hard tissue formation adjacent to implants of various size and configuration immediatel...
Publication Detail:
Type:  Journal Article; Review    
Journal Detail:
Title:  Advances in renal replacement therapy     Volume:  9     ISSN:  1073-4449     ISO Abbreviation:  Adv Ren Replace Ther     Publication Date:  2002 Apr 
Date Detail:
Created Date:  2002-06-26     Completed Date:  2003-01-10     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  9433799     Medline TA:  Adv Ren Replace Ther     Country:  United States    
Other Details:
Languages:  eng     Pagination:  125-32     Citation Subset:  IM    
Copyright Information:
Copyright 2002 by the National Kidney Foundation, Inc.
Affiliation:
Division of Nephrology, Department of Medicine, University of Missouri, Columbia, MO, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Catheters, Indwelling*
Humans
Kidney Failure, Chronic / therapy*
Peritoneal Dialysis / instrumentation*
Peritonitis / prevention & control
Sternum*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Moncrief-Popovich catheter and implantation technique: the AV fistula of peritoneal dialysis.