Document Detail


Pressure necrosis of the outlet septum caused by two adjacent implants.
MedLine Citation:
PMID:  22541202     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
A patient had a history of a Ross-Konno procedure, stenting of the pulmonary homograft, and an aortic valve replacement. Pressure necrosis developed in the tissues in between the stent and the prosthetic valve. This resulted in a defect between the right and left ventricular outflow tracts that required a complex operation for its correction.
Authors:
Antonio González-Calle; Alejandro Adsuar-Gomez; Amir-Reza Hosseinpour
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  The Annals of thoracic surgery     Volume:  93     ISSN:  1552-6259     ISO Abbreviation:  Ann. Thorac. Surg.     Publication Date:  2012 May 
Date Detail:
Created Date:  2012-04-30     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  15030100R     Medline TA:  Ann Thorac Surg     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  1704-6     Citation Subset:  AIM; IM    
Copyright Information:
Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Affiliation:
Department of Cardiac Surgery, University Hospitals Virgen del Rocio, Seville, Spain.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Starnes procedure in a neonate with pulmonary atresia and intact ventricular septum.
Next Document:  Bicuspid pulmonary valve with atrial septal defect leading to pulmonary aneurysm.