Document Detail


Preoperative evaluation of potential living related kidney donors with high-spatial-resolution magnetic resonance (MR) angiography at 3 Tesla: comparison with intraoperative findings.
MedLine Citation:
PMID:  18030197     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: The purpose of this prospective study was to determine the feasibility and accuracy of high-spatial-resolution MR imaging at 3 Tesla (T) in the preoperative evaluation of potential living related kidney donors. MATERIALS AND METHODS: Eighteen potential donors (8 men, 10 women; mean age, 50.1 +/- 14.2 years) for renal transplantation were evaluated with 3 T MR imaging. A high-spatial-resolution 3-dimensional (3D) gradient-echo MR angiography (repetition time/echo time, 3.0/1.14 ms; flip, 19-23 degrees; matrix, 512; slice thickness, 1.0 mm) using parallel acquisition technique (GRAPPA) with an acceleration factor of 3 was performed on a whole body scanner. Images were evaluated in a prospective and blinded fashion by 2 MR radiologists. The number of renal arteries, presence of early branches (defined as a branch arising within 2 cm of the main renal ostium), and renal artery stenosis were analyzed. The renal parenchyma, collecting system and ureters, were evaluated on the MR urograms. Interpretation of MR images were compared with surgical findings. RESULTS: Based on MR angiography data sets, a total of 36 main and 9 accessory renal arteries was found. There were 5 renal arteries presenting an early branching (<or=2 cm). The correct venous anatomy was identified in 13 of 14 patients (93%), including a single left renal vein anterior to the aorta (n = 3), retroaortic left renal vein (n = 2), and single right renal vein (n = 9). A single collecting system in all harvested kidneys was identified correctly with MR imaging. Overall, the sensitivity and positive predictive value of MRI in correctly determining the vascular and parenchymal anatomy in the harvested kidney was 85% and 93%, respectively. CONCLUSIONS: High-spatial-resolution contrast-enhanced MR angiography at 3 T can predict successful donor nephrectomy in potential living related kidney donors.
Authors:
Ulrich Kramer; Christian Thiel; Achim Seeger; Michael Fenchel; Gerhard Laub; Paul J Finn; Wolfgang Steurer; Claus D Claussen; Stephan Miller
Related Documents :
1727307 - Acute cerebral ischemia: evaluation with dynamic contrast-enhanced mr imaging and mr an...
12835977 - Multicenter phase-ii trial of safety and efficacy of nc100150 for steady-state contrast...
22161807 - Quantitative analysis of lumbar intervertebral disc abnormalities at 3.0 tesla: value o...
11496097 - Cross-sectional pattern of collateral vessels in patients with superficial femoral arte...
8314657 - Fundus pathology in neurosarcoidosis.
12069457 - Unenhanced helical ct in the investigation of acute flank pain.
Publication Detail:
Type:  Comparative Study; Controlled Clinical Trial; Journal Article    
Journal Detail:
Title:  Investigative radiology     Volume:  42     ISSN:  0020-9996     ISO Abbreviation:  Invest Radiol     Publication Date:  2007 Nov 
Date Detail:
Created Date:  2007-11-21     Completed Date:  2007-12-18     Revised Date:  2009-11-11    
Medline Journal Info:
Nlm Unique ID:  0045377     Medline TA:  Invest Radiol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  747-55     Citation Subset:  IM    
Affiliation:
Department of Diagnostic Radiology, University of Tuebingen, Tuebingen, Germany. ulrich.kramer@med.uni-tuebingen.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Family
Humans
Kidney Transplantation / pathology*
Living Donors
Magnetic Resonance Angiography / methods*
Male
Middle Aged
Patient Selection*
Preoperative Care / methods*
Prognosis
Renal Artery / abnormalities*,  pathology*
Renal Artery Obstruction / diagnosis*
Treatment Outcome

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Development of a composite material phantom mimicking the magnetic resonance parameters of the neona...
Next Document:  Assessment of global left and right ventricular function using dual-source computed tomography (DSCT...