Document Detail


Preoperative balloon sealing of a false ascending aortic aneurysm for safe redo sternotomy.
MedLine Citation:
PMID:  15919342     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Sternal contact of aortic aneurysms in redo operations may require specific techniques to safely control bleeding during sternotomy and surgical dissection. This is the first report on the preoperative use of an inflatable balloon to prevent massive hemorrhage by inserting the balloon--a procedure performed in the cardiac catheterization laboratory--before rethoracotomy. A false ascending aortic aneurysm was successfully sealed by transaortic wire-guided balloon placement from the iliac artery. Gentle traction on the inflated balloon catheter, which was placed inside the false aneurysm, effectively sealed the entrance to the aneurysm. A straightforward median redo sternotomy procedure was subsequently performed without blood loss from the unavoidably opened aneurysm. My colleagues and I propose this technique for aneurysms of mycotic or anastomotic origin, which have an anatomically distinct entry channel.
Authors:
Henning Warnecke; Norbert Franz; Stefan Roethemeyer; Frank Ritter; Alexander T John; Joachim Thale
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  The Annals of thoracic surgery     Volume:  79     ISSN:  1552-6259     ISO Abbreviation:  Ann. Thorac. Surg.     Publication Date:  2005 Jun 
Date Detail:
Created Date:  2005-05-27     Completed Date:  2006-08-08     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  15030100R     Medline TA:  Ann Thorac Surg     Country:  Netherlands    
Other Details:
Languages:  eng     Pagination:  2166-8     Citation Subset:  AIM; IM    
Affiliation:
Department of Cardiac Surgery, Schuechtermann-Klinik, Bad Rothenfelde, Germany. hwarnecke@schuechtermannklinik.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aneurysm, False / surgery*
Aneurysm, Infected / surgery
Aortic Aneurysm / surgery*
Balloon Dilatation / methods*
Hemorrhage / prevention & control*
Humans
Reoperation
Sternum / surgery*