Document Detail


Preliminary study of physiological control for the undulation pump ventricular assist device.
MedLine Citation:
PMID:  21096041     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
The undulation pump ventricular assist device (UPVAD) is a small implantable ventricular assist device using an undulation pump. The UPVAD can produce pulsatile flow by changing the motor rotation speed of the UPVAD. Because the undulation pump is a volume displacement type pump, the inflow sucking occurs easily. The purpose of this study is to develop a suitable control method for the UPVAD. The UPVAD inflow cannula equipped with an implantable pressure sensor was inserted into the ventricle. Therefore, pressure variation that synchronized with the natural heartbeat and negative pressure spike caused the inflow sucking were observed. By changing the motor rotation speed that responded to the inflow pressure, the UPVAD could synchronize with the natural heartbeat and the UPVAD could generate a co-pulse assist flow. The inflow sucking could be released by reducing the motor rotation speed, if the inflow sucking was detected. The newly developed control method exhibited superior characteristics than existing ones due to high immunity against pressure sensor drift. The assist flow could be increased more than 15% and the inflow sucking occurrence could be decreased with this control method. The UPVAD could generate the suitable assist flow with the developed control method.
Authors:
Itsuro Saito; Kohei Ishii; Takashi Isoyama; Toshiya Ono; Hidemoto Nakagawa; Wei Shi; Yusuke Inoue; Yusuke Abe
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference     Volume:  1     ISSN:  1557-170X     ISO Abbreviation:  Conf Proc IEEE Eng Med Biol Soc     Publication Date:  2010  
Date Detail:
Created Date:  2010-11-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101243413     Medline TA:  Conf Proc IEEE Eng Med Biol Soc     Country:  United States    
Other Details:
Languages:  eng     Pagination:  5218-21     Citation Subset:  IM    
Affiliation:
Department of Biomedical Engineering, Graduate School of Medicine, The University of Tokyo, Japan.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Evaluation of monitoring cardiac output by long time interval analysis of a radial arterial blood pr...
Next Document:  Automated drug delivery system for the management of hemodynamics and cardiac energetic in acute hea...