Abstract/OtherAbstract:
OBJECTIVES: The aim of this study was to evaluate the precision of the cephalometric analysis using the orthodontic software Orthometric((R)) in two modes: fully automatic without any help by the user and semiautomatic with manual determination of all cephalometric landmarks. METHODS: From 100 indirectly digitally produced cephalographs, 72 were chosen randomly. On each one of these, three methods were applied on 12 decision-relevant cephalometric angles according to Hasund/Segner: (1) hand drawing on a transparent sheet over the cephalographic film; (2) software semiautomatically with manual correction on the screen; and (3) fully automatically. The hand-based method (1) is well established as a quality standard and reference. The angle measurement results of this method were compared with those of the semiautomatic and the fully automatic method by calculation of the mean absolute differences. Additionally, five randomly chosen cephalographs were evaluated ten times using all three methods for statistical evaluation of reproducibility. RESULTS: At tenfold evaluation of five cephalographs, the standard deviations of the angles were between 0.05 degrees and 0.8 degrees . These results were similar using all three methods. All three methods had similar reproducibility. At evaluation of 72 cephalographs, the mean absolute angle differences between the hand-based (1) and semiautomatic (2) methods were below 2 degrees and so within the allowed tolerance limit, except for the nasolabial angle. In contrast to this, all mean absolute angle differences between the (1) hand-based and (3) fully automatic methods exceeded 2 degrees , and with this the tolerance limit allowed by literature. CONCLUSIONS: The fully automatic determination of the cephalometric landmarks has led to relevant errors up to now, so that it is mandatory to check all automatically set landmarks and to correct them if required. In the case of the semiautomatic method, all relevant angles can be determined with the same reliability as hand drawing.
Authors:
T Sommer; R Ciesielski; J Erbersdobler; W Orthuber; H Fischer-Brandies
Related Documents :
18642004 - Controlling a system with redundant degrees of freedom: ii. solution of the force distr...
19154064 - Optimal estimation of dynamically consistent kinematics and kinetics for forward dynami...
21120384 - Larva of seticeros aquilus (thomson) (coleoptera: cerambycidae: prioninae: callipogonini).
733464 - Analysis of variability in pylon transducer signals.
10738784 - Matched-field processing, geoacoustic inversion, and source signature recovery of blue ...
17047274 - Efficient schemes for robust imrt treatment planning.
Publication Detail:
Type:  Comparative Study; Evaluation Studies; Journal Article    
Journal Detail:
Title:  Dento maxillo facial radiology     Volume:  38     ISSN:  0250-832X     ISO Abbreviation:  Dentomaxillofac Radiol     Publication Date:  2009 Sep 
Date Detail:
Created Date:  2009-08-24     Completed Date:  2009-12-15     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7609576     Medline TA:  Dentomaxillofac Radiol     Country:  England    
Other Details:
Languages:  eng     Pagination:  401-6     Citation Subset:  D    
Affiliation:
Department of Orthodontics, Christian-Albrechts-University of Kiel, Kiel, Germany. sommer@kfo-zmk.uni-kiel.de
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Adult
Algorithms
Cephalometry / methods*,  standards
Child
Child, Preschool
Female
Humans
Image Processing, Computer-Assisted / methods*
Male
Middle Aged
Pattern Recognition, Automated
Radiography, Dental, Digital*
Reproducibility of Results
Software
User-Computer Interface
Young Adult

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effect of image compression of digital lateral cephalograms on the reproducibility of cephalometric ...
Next Document:  Evaluation of automatic exposure control in a direct digital intraoral system.