| Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. | |
| | |
MedLine Citation:
|
PMID: 20627878 Owner: NLM Status: MEDLINE |
Abstract/OtherAbstract:
|
BACKGROUND: Continuous non-invasive arterial pressure measured with CNAP (CNAP) has been shown to be superior to intermittent oscillometric measurements during procedural sedation and spinal anaesthesia. We assessed the performance of CNAP during general anaesthesia by analysis of agreement with invasive measurements of arterial pressure (AP). METHODS: Eighty-eight patients undergoing elective abdominal surgery, cardio-, or neurosurgery were included in the study. Systolic, diastolic, and mean AP measured by an intra-arterial catheter in the radial artery (IAP) were compared with those obtained by CNAP from the same arm. Data were analysed to determine the precision (i.e. measurement error) and accuracy (i.e. systematic error) of beat-to-beat CNAP values with respect to IAP. Also, we compared the frequency of fast changes in AP (FCAP) and hypotension (IOH) by both methods. RESULTS: CNAP precision of 4.5, 3.1, and 3.2 mm Hg (systolic, diastolic, and mean AP, respectively) was not significantly different from IAP precision, and CNAP accuracy was +6.7, -5.6, and -1.6 mm Hg. The frequency of AP pairs having a difference within the calculated limits of agreement was 81%, 64%, and 76% for systolic, diastolic, and mean AP, respectively. The calculated limits of agreement were +/-17.6, +/-11.4, and +/-12.0 mm, Hg, respectively. CNAP and IAP detected simultaneously to 82.1% FCAP and to 84.6% IOH. CONCLUSIONS: CNAP provides real-time estimates of arterial pressure comparable with those generated by an invasive intra-arterial catheter system during general anaesthesia. |
| | |
Authors:
|
C Jeleazcov; L Krajinovic; T Münster; T Birkholz; R Fried; J Schüttler; J Fechner |
Related Documents
:
|
8896298 - Finger arterial pressure measurement with finapres. 18927258 - Comparison of upper arm and forearm blood pressure. 3846318 - Accuracy of indirect measures of medication compliance in hypertension. 8123068 - Measurement of arterial closing pressure. 1887748 - The effect of positive end-expiratory pressure ventilation on atrial filling. 6051778 - Observations on the rhythmic variation in the cat carotid body chemoreceptor activity w... |
Publication Detail:
|
Type: Evaluation Studies; Journal Article; Research Support, Non-U.S. Gov't Date: 2010-07-13 |
Journal Detail:
|
Title: British journal of anaesthesia Volume: 105 ISSN: 1471-6771 ISO Abbreviation: Br J Anaesth Publication Date: 2010 Sep |
Date Detail:
|
Created Date: 2010-08-18 Completed Date: 2010-10-05 Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 0372541 Medline TA: Br J Anaesth Country: England |
Other Details:
|
Languages: eng Pagination: 264-72 Citation Subset: IM |
Affiliation:
|
Department of Anesthesiology, University of Erlangen-Nuremberg, Erlangen, Germany. christian.jeleazcov@kfa.imed.uni-erlangen.de |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
Adult Aged Aged, 80 and over Anesthesia, General* Blood Pressure Blood Pressure Determination / instrumentation, methods Blood Pressure Monitors* Female Humans Male Middle Aged Monitoring, Intraoperative / instrumentation*, methods Oscillometry / methods Prospective Studies Radial Artery / physiology Reproducibility of Results Signal Processing, Computer-Assisted |
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Effects of fentanyl infusion on tracheal intubation and emergence agitation in preschool children an...
Next Document: Effect of anaesthetic technique and other perioperative factors on cancer recurrence.