Abstract/OtherAbstract:
|
BACKGROUND: Oxygen therapy is an important therapeutic resource for patients with hypoxemia. When changing oxygen flowmeters, we have observed that sometimes even with the same oxygen flow setting as before, a different pulse oxygen saturation is obtained. OBJECTIVE: To analyze the precision and accuracy of flowmeters used in hospital settings. METHODS: An experimental study was performed to test oxygen flowmeters from a terciary hospital, by using a calibrated flow analyzer. Used and new flowmeters accuracy was tested by reading in the gas analyzer a single measurement at flow rates of 1, 3, 5, and 10 L/min in 91 flowmeters and they were compared using the Student's t test or Mann-Whitney U test. Flowmeter precision was tested by reading in the flow analyzer 3 repetitive measurements set at flow rates of 1, 3, 5, and 10 L/min in 11 flowmeters and the reproducibility of these measurements was conducted by using the intraclass correlation coefficient (ICC) and Friedman's test. RESULTS: The mean measured flow rates were slightly lower than the stipulated flow rate at 1 L/min, very close for 3 L/min and higher for 5 and 10 L/min flow rates. There was a large variability among the measurements from different flowmeters, mainly at low flow rates (1 and 3 L/min). There was no difference between new and used flowmeters at the flow rates measured, except at 10 L/min. Flowmeters precision analysis showed a good reproducibility in 3 repetitive measurements for each flow rate (ICC = 0.96 [0.95-0.99]). CONCLUSION: The flowmeters tested showed good precision and poor accuracy. |
| | |
Authors:
|
Josy Davidson; Claudia Gazzeta; Luciano C Torres; Jose R Jardim; Oliver A Nascimento |
Related Documents
:
|
22465434 - The age of transfused blood predicts hematocrit response among critically ill surgical ... 6286044 - Rapid appearance of intraventricularly administered neuropeptides in the peripheral cir... 3960284 - Studies on a case of hhh-syndrome (hyperammonemia, hyperornithinemia, homocitrullinuria). 4436444 - Characteristics of the relationship between the flow rate of tubular fluid and potassiu... 2230024 - Blood meal analysis of phlebotomus argentipes in eight districts of west bengal. 8944984 - Influence of non pulsatile systemic circulation on tissue blood flow and oxygen metabol... |
Publication Detail:
|
Type: JOURNAL ARTICLE Date: 2012-1-23 |
Journal Detail:
|
Title: Respiratory care Volume: - ISSN: 0020-1324 ISO Abbreviation: - Publication Date: 2012 Jan |
Date Detail:
|
Created Date: 2012-1-25 Completed Date: - Revised Date: - |
Medline Journal Info:
|
Nlm Unique ID: 7510357 Medline TA: Respir Care Country: - |
Other Details:
|
Languages: ENG Pagination: - Citation Subset: - |
Export Citation:
|
APA/MLA Format Download EndNote Download BibTex |
| MeSH Terms | |
Descriptor/Qualifier:
|
|
From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine
Previous Document: Surgical Treatment for Thyrotoxic Hypokalemic Periodic Paralysis: Case Report.
Next Document: The Effect of Stylet Choice on the Success Rate of Intubation Using the GlideScope Video Laryngoscop...