Document Detail


Practical use and efficiency of amniotic fluid OD 650 as a predictor of fetal pulmonary maturity.
MedLine Citation:
PMID:  6835607     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Fetal pulmonary maturity evaluation was performed on 237 amniotic fluid specimens from 202 gravidas using: 1) optical density (OD) 650, 2) shake or foam stabilization test, and 3) lecithin: sphingomyelin ratio. One hundred thirty-one gravidas delivered within 48 hours of specimen collection, including nine of 11 women delivering respiratory distress syndrome-affected infants and 40 delivering premature infants. The efficiency of each test in predicting fetal pulmonary maturity status was calculated and showed that statistically, OD 650 was significantly better at predicting fetal pulmonary maturity in preterm infants and all infants. Twenty-six of 27 infants of diabetic mothers (classes A through R) had mature OD 650 values; none developed respiratory distress syndrome. The authors confirm that the OD 650 is reliable in most clinical settings and superior to the shake test. The authors recommended its primary use when sophisticated phospholipid studies are not immediately available.
Authors:
R J Turner; J A Read
Related Documents :
480037 - Primary pulmonary hypoplasia in the neonate.
15251147 - Iatrogenic damage in the neonatal period.
202067 - Degenerative processes in the pathogenesis of pulmonary alveolar lipoproteinosis.
2423997 - Massive metastatic pulmonary calcification in an infant with aleukemic monocytic leukemia.
22436417 - Near-infrared spectroscopy: a report from the mcdonnell infant methodology consortium.
1304077 - The effects of luminance on fpl and vep acuity in human infants.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Obstetrics and gynecology     Volume:  61     ISSN:  0029-7844     ISO Abbreviation:  Obstet Gynecol     Publication Date:  1983 May 
Date Detail:
Created Date:  1983-05-27     Completed Date:  1983-05-27     Revised Date:  2009-10-26    
Medline Journal Info:
Nlm Unique ID:  0401101     Medline TA:  Obstet Gynecol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  551-5     Citation Subset:  AIM; IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Amniotic Fluid / analysis*
Densitometry*
Fetal Organ Maturity*
Humans
Lung / embryology*
Optics and Photonics

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Patterns of alcohol consumption and fetal development.
Next Document:  Effect of tocolysis on incidence of low birth weight.