Postural influence on the neutral zone of the porcine cervical spine under anterior-posterior shear load.
MedLine Citation:
PMID:  22989527     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Segmental instability, characterized by excessive or aberrant movement of the vertebrae can be assessed quantitatively using mechanical characteristics within a region of minimal resistance called the neutral zone. The diagnosis of instability is often used to decide whether or not to surgically fuse the vertebrae. Alterations in flexion/extension posture cause changes in both contact area and spacing between articulating facets that may lead to changes in the mechanical response of the functional spinal unit (FSU) within the neutral zone. This investigation quantified neutral zone (NZ) length under anterior and posterior shear loading and the influence of posture on the shear NZ characteristics of the vertebral joint. Thirty porcine cervical FSUs (15 C34 and 15 C56) were tested. Endplate area was calculated from measurements of the exposed endplates while facet angles were measured from X-rays taken in the transverse plane. Specimens were exposed to a 300N compressive preload followed by a test to determine flexion/extension NZ limits. These limits were used as target angles during shear passive tests performed in extended and flexed postures. Displacement rate during shear passive tests was 0.2mm/s and five cycles of anterior-posterior shear were performed to a target of ±400N in a randomized order of extended, neutral and flexed postures. Shear NZ length and average stiffness were quantified. Stiffness within the shear NZ was 67N/mm in the neutral posture. Extended postures produced a 37% (p<0.0001) increase in shear stiffness within the NZ compared to both flexed and neutral postures. Posture did not influence shear NZ length. Therefore, a true region of zero stiffness does not exist during shear loading with a baseline compressive load. Neutral zone length for the porcine FSU exposed to shear load was not influenced, despite known changes in facet articulation, by changing posture. Average stiffness increased likely as a result of increased contact area and force in extension. The results from this investigation demonstrate that postural deviation of the vertebral joint is not likely a significant confounding factor when assessing segmental stability.
Authors:
Samuel J Howarth; Kaitlin M Gallagher; Jack P Callaghan
Related Documents :
23740367 - Synchronous emg activity in the piper frequency band reveals the corticospinal demand o...
23131017 - The categorisation of swimming start performance with reference to force generation on ...
23574577 - Inulin and erythritol as sucrose replacers in short-dough cookies: sensory, fracture, a...
24071587 - Testing the horizontal-vertical stereo anisotropy with the critical-band masking paradigm.
25126057 - Two distinct olfactory bulb sublaminar networks involved in gamma and beta oscillation ...
1541247 - Reliability of individual differences for h-reflex recordings.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-9-15
Journal Detail:
Title:  Medical engineering & physics     Volume:  -     ISSN:  1873-4030     ISO Abbreviation:  Med Eng Phys     Publication Date:  2012 Sep 
Date Detail:
Created Date:  2012-9-19     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9422753     Medline TA:  Med Eng Phys     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.
Affiliation:
Department of Graduate Education and Research, Canadian Memorial Chiropractic College, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A homozygous splice site mutation in TRAPPC9 causes intellectual disability and microcephaly.
Next Document:  Investigation of metallic and carbon fibre PEEK fracture fixation devices for three-part proximal hu...