Output intensity patterns and total throughput for plastic fiber optic systems were measured as a function of input direction. For increasingly oblique input, the output pattern approached a conical shell and total throughput decreased. The decrease of total throughput was faster than expected from geometrical considerations and was interpreted in terms of loss at reflection from the core-sheath interface. Analysis indicated (a) that the reflection loss was of the order of 10(-4) for angles of incidence >/= 70 degrees , (b) that interface quality was high and imperfections contributed relatively little to this loss except for angles of incidence near 90 degrees , and (c) that this loss was principally due to sheath penetration at internal reflection for most angles of incidence greater than the critical angle. The effective absorption coefficient of the sheath derived from this analysis was larger than the absorption coefficient measured for bulk sheath polymer.
Authors:
R G Brown; B N Derick
Related Documents :
11936789 - Fiber-optic infrared radiometer for accurate temperature measurements.
19547449 - Corrugated metal-coated tapered tip for scanning near-field optical microscope.
20700239 - Coupling of high power laser diode optical power.
19529229 - Formation of long and thin polymer fiber using nondiffracting beam.
20720679 - Passive optical fiber star coupler.
19829629 - Solitonlike optical switching in a circular fiber array.
11690119 - Embedding of multidimensional time-dependent observations.
23893199 - Exploiting jump-resonance hysteresis in silicon auditory front-ends for extracting spea...
8505209 - Optical zone diameters for photorefractive corneal surgery.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Applied optics     Volume:  8     ISSN:  0003-6935     ISO Abbreviation:  Appl Opt     Publication Date:  1969 Feb 
Date Detail:
Created Date:  2010-01-14     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0247660     Medline TA:  Appl Opt     Country:  United States    
Other Details:
Languages:  eng     Pagination:  437-42     Citation Subset:  -    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Radiant power flow and absorptance in thin films.
Next Document:  An ultrasonic shutter for noise reduction in real-time optical correlators.