BACKGROUND: Mechanical stress at the plantar surface has two components, pressure acting normal to the surface and shear stress acting tangential to the surface. Typically only pressure is measured and reported. However, plantar shear stress also plays a major role, especially in diabetic ulceration.
METHODS: During the last few decades, a variety of methods have been developed for the measurement of plantar shear stress. This paper reviews the technologies used in plantar shear stress measurements.
FINDINGS: Several technologies have been used, e.g. magneto-resistors, strain gauges, optical methods, piezoelectric materials and capacitive sensors. Examples of plantar shear stress values measured with the developed devices are also collected here and the relationship between sensor characteristics and the measured plantar shear stress distribution is discussed.
INTERPRETATION: Even with the limitations of current plantar shear stress measurement technologies, they can provide useful information on the plantar stress distribution.
Authors:
Satu Née Kärki Rajala; Jukka Lekkala
Related Documents :
2502935 - Effects of clonidine on anesthetic drug requirements and hemodynamic response during ao...
11350495 - Acute renal failure in 2k2c goldblatt hypertensive rats during antihypertensive therapy...
9729575 - Vascular resistance and the efficacy of red cell substitutes in a rat hemorrhage model.
1737075 - Noradrenergic function in panic disorder. effects of intravenous clonidine pretreatment...
18454345 - Association of cholesteryl ester transfer protein (taqib) and apolipoprotein e (hhai) g...
17759095 - Magnesium compounds: new dense phases.
Publication Detail:
Type:  REVIEW     Date:  2014-4-26
Journal Detail:
Title:  Clinical biomechanics (Bristol, Avon)     Volume:  -     ISSN:  1879-1271     ISO Abbreviation:  Clin Biomech (Bristol, Avon)     Publication Date:  2014 Apr 
Date Detail:
Created Date:  2014-5-13     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8611877     Medline TA:  Clin Biomech (Bristol, Avon)     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2014 Elsevier Ltd. All rights reserved.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  The relationship between knee joint loading rate during walking and degenerative changes on magnetic...
Next Document:  Risk Factors Associated with Complication Following Gastrectomy for Gastric Cancer: Retrospective An...