Document Detail


Placement of trans-sternal wires according to an ellipsoid pressure vessel model of sternal forces.
MedLine Citation:
PMID:  22186126     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Dehiscence of median sternotomy wounds remains a clinical problem. Wall forces in thin-walled pressure vessels can be calculated by membrane stress theory. An ellipsoid pressure vessel model of sternal forces is presented together with its application for optimal wire placement in the sternum. Sternal forces were calculated by computational simulation using an ellipsoid chest wall model. Sternal forces were correlated with different sternal thicknesses and radio-density as measured by computerized tomography (CT) scans of the sternum. A comparison of alternative placement of trans-sternal wires located either at the levels of the costal cartilages or the intercostal spaces was made. The ellipsoid pressure vessel model shows that higher levels of stress are operative at increasing chest diameter (P < 0.001). CT scans show that the thickness of the sternal body is on average 3 mm and 30% thicker (P < 0.001) and 53% more radio-dense (P < 0.001) at the costal cartilage levels when compared with adjacent intercostal spaces. This results in a decrease of average sternal stress from 438 kPa at the intercostal space level to 338 kPa at the costal cartilage level (P = 0.003). Biomechanical modelling suggests that placement of trans-sternal wires at the thicker bone and more radio-dense level of the costal cartilages will result in reduced stress.
Authors:
Aaron R Casha; Alex Manché; Marilyn Gauci; Marie-Therese Camilleri-Podesta; Pierre Schembri-Wismayer; Zdenka Sant; Ruben Gatt; Joseph N Grima
Related Documents :
21727516 - Fabrication of zinc oxide nanostructures using solvent-assisted capillary lithography.
3012056 - Changes in cerebral blood volume and cytochrome aa3 during hypertensive peaks in preter...
1468556 - Air saturation of the medium reduces the rate of phosphorylating oxidation of succinate...
21568416 - Distribution of standing-wave errors in real-ear sound-level measurements.
20622106 - Continuous and less invasive central hemodynamic monitoring by blood pressure waveform ...
17683636 - Cardiovascular responses to cognitive stress in patients with migraine and tension-type...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-12-20
Journal Detail:
Title:  Interactive cardiovascular and thoracic surgery     Volume:  -     ISSN:  1569-9285     ISO Abbreviation:  -     Publication Date:  2011 Dec 
Date Detail:
Created Date:  2011-12-21     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101158399     Medline TA:  Interact Cardiovasc Thorac Surg     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Cardiothoracic Surgery, Mater Dei Hospital, Msida, Malta.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Blood pressure control in treated hypertensive patients in daily practice of latvian family physicia...
Next Document:  Bronchial mucous gland adenoma revealed following acute pneumonia.