Document Detail


The placement of skin surface markers for non-invasive measurement of scapular kinematics affects accuracy and reliability.
MedLine Citation:
PMID:  20967500     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
Abnormal scapular movement is widely believed to be an important factor in clinical pathology of the shoulder joint complex. Validated non-invasive techniques for measuring scapular movement have been developed, but the effect of marker placement on accuracy is unknown. The objective of this study was to determine the accuracy and reliability of different groupings of markers to achieve the best accuracy and reliability for measuring scapular kinematics. Eight healthy young adult subjects were recruited. An optoelectronic marker grid was applied to the skin overlying the scapula. Two bone pins with optoelectronic marker carriers were inserted into the scapula. The accuracy of six surface marker configurations was determined by comparing the measured kinematics with scapular bone pins (the gold standard). Four humeral movements were tested: glenohumeral abduction, glenohumeral horizontal adduction, hand behind back, and forward reaching. All three rotations had a significant difference in the accuracy of the patches (p = 0.04 to p < 0.0001). For posterior tipping there was a significant effect of movement (p = 0.003) and a significant interaction (p < 0.0001). There was also a significant interaction for external rotation (p = 0.001). The marker grouping with the largest cranio-caudal spread had the highest accuracy for measuring posterior tilting (RMS 1.9°). Markers closer to the scapular spine were more accurate for tracking external rotation (RMS 2.0°) while an intermediate grouping of markers were most accurate for quantifying upward rotation (RMS 1.9°). The reliability between days ranged between 3.8° and 7.5° (based on RMS difference between trials) and there was a significant interaction between patch and movement (p < 0.0001). Intraclass correlation coefficients show moderate to good agreement for most arm movements and scapular rotations. Thus, there exists distinct optimal configurations of non-invasive marker locations for accurately measuring scapular kinematics.
Authors:
Douglas A Bourne; Anthony M Choo; William D Regan; Donna L Macintyre; Thomas R Oxland
Publication Detail:
Type:  Journal Article     Date:  2010-10-22
Journal Detail:
Title:  Annals of biomedical engineering     Volume:  39     ISSN:  1521-6047     ISO Abbreviation:  Ann Biomed Eng     Publication Date:  2011 Feb 
Date Detail:
Created Date:  2011-02-04     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0361512     Medline TA:  Ann Biomed Eng     Country:  United States    
Other Details:
Languages:  eng     Pagination:  777-85     Citation Subset:  IM    
Affiliation:
Orthopaedic and Injury Biomechanics Group, Departments of Orthopaedics and Mechanical Engineering, University of British Columbia and Vancouver Coastal Health Research Institute, 818 West 10th Avenue, Vancouver, BC, V5Z 1L8, Canada.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Five new species of yeasts from fresh water and marine habitats in the Florida Everglades.
Next Document:  A review of the ultrastructural features of superficial candidiasis.