Document Detail


Pitfalls of the concept of incremental specificity used in comparisons of dual chamber VT/VF detection algorithms.
MedLine Citation:
PMID:  10914375     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The concepts of incremental specificity and incremental positive predictive accuracy (PPA) have been proposed to measure the success of dual chamber cardioverter defibrillator (ICD) algorithms for tachyarrhythmia detection in improving specificity while maintaining very high sensitivity to detection of episodes of ventricular tachycardia/fibrillation (VT/VF). While dual chamber VT/VF detection algorithms differ substantially among different ICD manufacturers, they all operate as "add-on" features to the single chamber elementary detection algorithms that are based on simple criteria of increased ventricular rate. The incremental specificity and PPA characterize the performance of the dual chamber detection operation in this "add-on" mode, that is within a database of rhythm episodes all meet the simple rate-based criteria. A statistical model of hypothetical devices has been used to demonstrate that the concepts of incremental specificity and PPA are very dependent on the composition of the database used to evaluate a particular dual chamber ICD. Because some sinus tachycardia and supraventricular tachyarrhythmias with regular atrioventricular conduction are more easily discriminated from true VT/VF than other supraventricular tachyarrhythmias, the model shows that rather than the performance of the dual chamber detection functions, the major contributor to the incremental specificity may be the proportion between the "easy" and "difficult" supraventricular episodes. The algorithms used by different ICD manufacturers to detect tachyarrhythmias based on ventricular rate are known to differ substantially in the ability to differentiate true VT/VF from other tachyarrhythmias. Consequently, the databases of rhythms against which the different dual camber ICDs are tested are also different in composition of different types of supraventricular tachyarrhythmias. Therefore, the values of incremental specificity and PPA reported by different manufacturers do not have an equivalent meaning and do not offer a valid comparison of the true performance of different dual chamber ICDs.
Authors:
M Malik
Related Documents :
25114965 - A novel clustering algorithm for mobile ad hoc networks based on determination of virtu...
20628585 - Integrative computational models of cardiac arrhythmias -- simulating the structurally ...
23611195 - Bayesian adaptive d-optimal design with delayed responses.
22938645 - Lesser toes proximal interphalangeal joint fusion in rigid claw toes.
6517075 - A multivariate statistical method for the establishment of maximum allowable exposure t...
21167475 - Prediction of psychosis by mismatch negativity.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  23     ISSN:  0147-8389     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  2000 Jul 
Date Detail:
Created Date:  2000-12-01     Completed Date:  2000-12-01     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1166-70     Citation Subset:  IM    
Affiliation:
Department of Cardiological Sciences, St. George's Hospital Medical School, London, England. m.malik@sghms.ac.uk
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Algorithms*
Defibrillators, Implantable* / statistics & numerical data
Humans
Models, Statistical
Predictive Value of Tests
Sensitivity and Specificity
Tachycardia, Ventricular / diagnosis*,  therapy
Ventricular Fibrillation / diagnosis*,  therapy

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Dual demand pacing using retriggerable refractory periods for ventricular rate control during paroxy...
Next Document:  Radiofrequency catheter ablation from the left sinus of Valsalva in a patient with idiopathic ventri...