Physical and clinical performance of the mCT time-of-flight PET/CT scanner.
MedLine Citation:
PMID:  21427485     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
Time-of-flight (TOF) measurement capability promises to improve PET image quality. We characterized the physical and clinical PET performance of the first Biograph mCT TOF PET/CT scanner (Siemens Medical Solutions USA, Inc.) in comparison with its predecessor, the Biograph TruePoint TrueV. In particular, we defined the improvements with TOF. The physical performance was evaluated according to the National Electrical Manufacturers Association (NEMA) NU 2-2007 standard with additional measurements to specifically address the TOF capability. Patient data were analyzed to obtain the clinical performance of the scanner. As expected for the same size crystal detectors, a similar spatial resolution was measured on the mCT as on the TruePoint TrueV. The mCT demonstrated modestly higher sensitivity (increase by 19.7 ± 2.8%) and peak noise equivalent count rate (NECR) (increase by 15.5 ± 5.7%) with similar scatter fractions. The energy, time and spatial resolutions for a varying single count rate of up to 55 Mcps resulted in 11.5 ± 0.2% (FWHM), 527.5 ± 4.9 ps (FWHM) and 4.1 ± 0.0 mm (FWHM), respectively. With the addition of TOF, the mCT also produced substantially higher image contrast recovery and signal-to-noise ratios in a clinically-relevant phantom geometry. The benefits of TOF were clearly demonstrated in representative patient images.
Authors:
B W Jakoby; Y Bercier; M Conti; M E Casey; B Bendriem; D W Townsend
Related Documents :
21458865 - Superior semicircular canal dehiscence and enlarged vestibular aqueduct.
10815675 - Diffusion-weighted mr imaging offers no advantage over routine noncontrast mr imaging i...
11230665 - Hemangiomas of the fingers: mr imaging evaluation.
7622675 - Pineal parenchymal tumors: ct and mr features.
110075 - Intraabdominal abscess: current concepts in radiologic evaluation.
3966125 - Magnetic resonance imaging of the brainstem: normal structure and basic functional anat...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-3-22
Journal Detail:
Title:  Physics in medicine and biology     Volume:  56     ISSN:  1361-6560     ISO Abbreviation:  -     Publication Date:  2011 Mar 
Date Detail:
Created Date:  2011-3-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  2375-2389     Citation Subset:  -    
Affiliation:
Department of Physics, University of Surrey, Guildford, Surrey, UK. University of Tennessee Medical Center, Knoxville, TN, USA. Siemens Medical Solutions USA, Inc., Knoxville, TN, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Response functions for computing absorbed dose to skeletal tissues from photon irradiation-an update...
Next Document:  Frequency-dependent viscoelastic parameters of mouse brain tissue estimated by MR elastography.