Phantoms for quality control procedures in digital breast tomosynthesis: dose assessment.
MedLine Citation:
PMID:  23756494     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
The recent introduction of digital breast tomosynthesis into clinical practice requires quality control procedures. In this study we have investigated whether the assessment of the average glandular dose for modelled standard breasts can be performed using a combination of polymethyl methacrylate (PMMA) and polyethylene (PE) slabs that matches standard breast thicknesses. For this purpose the energies absorbed per unit area of the image receptor when imaging standard breasts and PMMA-PE slabs have been matched taking account of both primary and scattered photons. To achieve this a two-step approach was used. Firstly, the behaviour of the scatter-to-primary ratio (SPR) of PMMA-PE phantoms and standard breasts was investigated using Monte Carlo simulations for various conditions. For imaging without an anti-scatter grid, it was found that the values of standard breast and phantom SPR were significantly different and it follows that these differences are relevant when matching the absorbed energy. In the second part, a set of PMMA-PE combinations is proposed which, for dosimetric purposes, can be used to simulate standard breasts in the thickness range 20 to 100 mm. The dosimetric error when using these PMMA-PE slabs was found to be below 6% for thicknesses up to 7 cm and increases to 10% for 10 cm thickness.
Authors:
R W Bouwman; O Diaz; R E van Engen; K C Young; G J den Heeten; M J M Broeders; W J H Veldkamp; D R Dance
Related Documents :
24212814 - Systematic review of breast cancer biology in developing countries (part 1): africa, th...
24419734 - Cardiorespiratory fitness in breast cancer patients: a call for normative values.
1463294 - Nonsquamous carcinomas of the larynx.
24596364 - Low protein expression of met in er-positive and her2-positive breast cancer.
20647404 - Serum free circulating dna is a useful biomarker to distinguish benign versus malignant...
23230974 - Correlation of age and hrt use with breast density as assessed by quantra(™).
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-6-12
Journal Detail:
Title:  Physics in medicine and biology     Volume:  58     ISSN:  1361-6560     ISO Abbreviation:  Phys Med Biol     Publication Date:  2013 Jun 
Date Detail:
Created Date:  2013-6-12     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0401220     Medline TA:  Phys Med Biol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  4423-4438     Citation Subset:  -    
Affiliation:
National Expert and Training Centre for Breast Cancer Screening, Radboud University Nijmegen Medical Centre (LRCB), Weg door Jonkerbos 90, 6532 SZ Nijmegen, The Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  A supramolecular DNA self-assembly based on ?-cyclodextrin-adamantane complexation as a bioorthogona...
Next Document:  Copper-catalyzed annulation of amidines for quinazoline synthesis.