Document Detail


Peritonitis prevented in continuous ambulatory peritoneal dialysis by using the Hong Kong connection.
MedLine Citation:
PMID:  6419925     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Based on the hypothesis that air contamination is an important cause of peritonitis in continuous ambulatory peritoneal dialysis, a simple and cheap connection system was developed whereby a clear polyethylene bag containing an antiseptic gauze was used as a sterilising chamber, effectively enclosing the connection procedure. Seven modifications to the connection technique were introduced over 32 months in 28 patients during 27.9 patient years of experience. The overall rate of peritonitis was 0.6 episode/patient year, but after a final modification at the beginning of the third year the rate fell to 0.17, without a single case of peritonitis occurring attributable to a connection failure in 11.5 patient years. These findings show that in patients receiving continuous ambulatory peritoneal dialysis peritonitis may be prevented by enclosing the connection process and sterilising the introduced air and tubing ends.
Authors:
R D Clark
Related Documents :
19886315 - Peritoneal dialysis patients with high effluent fibrin degradation products.
21698055 - The association among lipoprotein-associated phospholipase a2 levels, total antioxidant...
12897415 - Deformability and enzymes activities of red blood cells in hemodialysed and peritoneal ...
8534695 - Infection rates in end-stage renal disease patients treated with ccpd and capd using th...
298995 - Epilepsy as a sequel to cerebrovascular accident.
451835 - Protein supplementation in the management of degenerating liver function after jejunoil...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  British medical journal (Clinical research ed.)     Volume:  288     ISSN:  0267-0623     ISO Abbreviation:  Br Med J (Clin Res Ed)     Publication Date:  1984 Feb 
Date Detail:
Created Date:  1984-03-21     Completed Date:  1984-03-21     Revised Date:  2009-11-18    
Medline Journal Info:
Nlm Unique ID:  8302911     Medline TA:  Br Med J (Clin Res Ed)     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  353-6     Citation Subset:  AIM; IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Air
Humans
Peritoneal Dialysis / instrumentation*
Peritoneal Dialysis, Continuous Ambulatory / instrumentation*,  methods
Peritonitis / prevention & control*
Sterilization / instrumentation
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Autoantibodies against human insulin.
Next Document:  Measurement of serum amyloid A protein concentrations as test of renal allograft rejection in patien...