Performance of two blue light-emitting-diode dental light curing units with distance and irradiation-time.
MedLine Citation:
PMID:  14698776     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
OBJECTIVES: To assess the performance of two blue light-emitting-diode (LED) curing units, in terms of their spectral output and irradiance and the depth of cure (dcure) produced in standard hybrid and modified composites, compared with a conventional quartz tungsten halogen (QTH) light curing unit. METHODS: The following light curing units (LCUs) were studied: Elipar-Freelight-1 LED (LED-1) 3 M-ESPE, Ultralume-2 LED (LED-2) Optident, and the Optilux-500 QTH (QTH-1) Sybron-Kerr. For each LCU, using a UV-visible spectrophotometer, the output spectrum was measured and the irradiance of emitted light as a function of source-detector distance. Three composites were studied of similar formulation but differing in their initiator concentrations and/or opacity. These were: Tetric Ceram (A3), Tetric Ceram HB containing an additional photoinitiator responding to approximately 435 nm (A3) and Tetric Ceram Bleach (L). dcure was measured using a calibrated digital needle-penetrometer, as a function of source-specimen distance and for irradiance periods of 10, 20 and 40 s. RESULTS: Each unit delivered a single peak in the blue region of the visible spectrum. The wavelength maxima for LED-1, LED-2 and QTH-1 were 486.4, 458.2 and 495.2 nm, respectively. Cure-depth (dcure) values varied significantly (p<0.001) with irradiance times and source-specimen distance for both LED and QTH sources. The percentage reduction in dcure values resulting from LED versus QTH irradiance increased with source-specimen distance. SIGNIFICANCE: The LED-LCUs had an energy-efficient spectral output for conventional composite curing but had a lower irradiance compared with the QTH-LCU, leading to reduced performance in depths of cure. Design improvements to provide greater irradiance from the LED-1 and to a lesser extent LED-2, should result in increased performance.
Authors:
Adrian W Bennett; David C Watts
Related Documents :
18722976 - The use of narrowband imaging for identification of endometriosis.
21217946 - Dental ceramics: an update.
19089216 - Influence of energy density of different light sources on knoop hardness of a dual-cure...
18614226 - Polymerization shrinkage strain of interocclusal recording materials.
25040446 - Evaluation of the appreciation of virtual teeth with and without pathology.
23981256 - Scientific evaluation and pricing of medical devices and associated procedures in france.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Dental materials : official publication of the Academy of Dental Materials     Volume:  20     ISSN:  0109-5641     ISO Abbreviation:  Dent Mater     Publication Date:  2004 Jan 
Date Detail:
Created Date:  2003-12-30     Completed Date:  2004-03-30     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  8508040     Medline TA:  Dent Mater     Country:  England    
Other Details:
Languages:  eng     Pagination:  72-9     Citation Subset:  D    
Affiliation:
Biomaterials Science Unit, Turner Dental School, University of Manchester, Higher Cambridge Street, Manchester M15 6FH, UK. awbennett@btopenworld.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Analysis of Variance
Composite Resins / radiation effects*
Dental Equipment*
Electric Power Supplies
Halogens
Light
Radiometry
Semiconductors*
Technology, Dental / instrumentation
Time Factors
Chemical
Reg. No./Substance:
0/Composite Resins; 0/Halogens

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  In vitro contact wear of dental composites.
Next Document:  Second generation LEDs for the polymerization of oral biomaterials.