Performance characteristics of a commercial dedicated contamination counter.
MedLine Citation:
PMID:  1989949     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The dedicated wipe test counter (DWTC) is a commercial geiger-counter type instrument especially designed for wipe test counting. All samples are counted under the same physical conditions within 0.3 cm from a 2-mg cm-2 mica end-window geiger tube of 1.27 cm in diameter. The counting capabilities of the DWTC were tested for different radioisotopes in common use in the nuclear medicine laboratory. Since most of the imaging agents are 99mTc-based radiopharmaceuticals, an experimental efficiency factor, J = 3 cpm kdpm-1, was determined for this radioisotope by the manufacturer and stored in the counting system for default use. In addition, the formulation for the counting time needed to achieve a measurement with adequate level of significance (two standard deviations) and a background measurement time of 20 min was programmed in the firmware of the DWTC. With these parameters, the counting time for a 99mTc wipe (threshold of 2000 dpm) becomes 1.88 min for a background level of 10 cpm. The counting time increases to 3.25 and 4.80 min for the respective background levels of 20 and 30 cpm while the threshold is kept the same. In practice, we were able to measure activities as low as 0.7 kdpm for 99mTc and 0.09 kdpm for 131I. Linearity was maintained for a wide range of activities for all tested radioisotopes. The DWTC was found to be simple to operate and satisfies all requirements for performing wipe tests in the nuclear medicine laboratory.
Authors:
S Hoory; D Bandyopadhyay; W E Simon; H Malamud; D Margouleff
Related Documents :
7424929 - Drug interferences with tests performed by a 12-channel autoanalyzer.
18841439 - Major inter-laboratory variations in psa testing practices: results from national surve...
24496349 - Does usage of peritonism tests in an emergency department have any benefit?
24717779 - Allergic sensitization to ornamental plants in patients with allergic rhinitis and asthma.
24661449 - Role of laparoscopy and ultrasound in the management of "impalpable testis" in children.
3887879 - Smell of danger: an analysis of lp-gas odorization.
17183699 - Surprisingly high specificity of the ppd skin test for m. tuberculosis infection from r...
417649 - In vitro lymphocyte transformation as a herd survey method for bovine paratuberculosis.
23818169 - Fecal inmunochemical test accuracy in familial risk colorectal cancer screening.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Health physics     Volume:  60     ISSN:  0017-9078     ISO Abbreviation:  Health Phys     Publication Date:  1991 Feb 
Date Detail:
Created Date:  1991-03-01     Completed Date:  1991-03-01     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  2985093R     Medline TA:  Health Phys     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  269-74     Citation Subset:  IM    
Affiliation:
Division of Nuclear Medicine, Long Island Jewish Medical Center, New Hyde Park, NY.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Evaluation Studies as Topic
Laboratories*
Nuclear Medicine*
Radioisotopes / analysis*
Radiometry*
Chemical
Reg. No./Substance:
0/Radioisotopes

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Hand dose measurements in interventional radiology.
Next Document:  Change-of-life anticipations, attitudes, and experiences among middle-aged Danish women.