Document Detail


Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy.
MedLine Citation:
PMID:  21441548     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: /st> Arterial pressure waveform analysis of cardiac output (APCO) without external calibration (FloTrac/Vigileo™) is critically dependent upon computation of vascular tone that has necessitated several refinements of the underlying software algorithms. We hypothesized that changes in vascular tone induced by high-dose vasopressor therapy affect the accuracy of APCO measurements independently of the FloTrac software version. METHODS: /st> In this prospective observational study, we assessed the validity of uncalibrated APCO measurements compared with transpulmonary thermodilution cardiac output (TPCO) measurements in 24 patients undergoing vasopressor therapy for the treatment of cerebral vasospasm after subarachnoid haemorrhage. RESULTS: /st> Patients received vasoactive support with [mean (sd)] 0.53 (0.46) µg kg(-1) min(-1) norepinephrine resulting in mean arterial pressure of 104 (14) mm Hg and mean systemic vascular resistance of 943 (248) dyn s(-1) cm(-5). Cardiac output (CO) data pairs (158) were obtained simultaneously by APCO and TPCO measurements. TPCO ranged from 5.2 to 14.3 litre min(-1), and APCO from 4.1 to 13.7 litre min(-1). Bias and limits of agreement were 0.9 and 2.5 litre min(-1), resulting in an overall percentage error of 29.6% for 68 data pairs analysed with the second-generation FloTrac(®) software and 27.9% for 90 data pairs analysed with the third-generation software. Precision of the reference technique was 2.6%, while APCO measurements yielded a precision of 29.5% and 27.9% for the second- and the third-generation software, respectively. For both software versions, bias (TPCO-APCO) correlated inversely with systemic vascular resistance. CONCLUSIONS: /st> In neurosurgical patients requiring high-dose vasopressor support, precision of uncalibrated CO measurements depended on systemic vascular resistance. Introduction of the third software algorithm did not improve the insufficient precision (>20%) for APCO measurements observed with the second software version.
Authors:
S Metzelder; M Coburn; M Fries; M Reinges; S Reich; R Rossaint; G Marx; S Rex
Related Documents :
11485288 - Sympathetic rhythms and cardiovascular oscillations.
17726508 - Postprandial hypotension due to a lack of sympathetic compensation in patients with dia...
10694528 - Oscillatory patterns in sympathetic neural discharge and cardiovascular variables durin...
21549298 - Accuracy of doppler echocardiography to estimate key hemodynamic variables in subjects ...
12045368 - Therapeutic considerations in the treatment of obesity hypertension.
23790318 - Dynamic structural changes in microbial membranes in response to high hydrostatic press...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-3-25
Journal Detail:
Title:  British journal of anaesthesia     Volume:  -     ISSN:  1471-6771     ISO Abbreviation:  -     Publication Date:  2011 Mar 
Date Detail:
Created Date:  2011-3-28     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0372541     Medline TA:  Br J Anaesth     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Anaesthesiology.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Respiratory systolic variation test in acutely impaired cardiac function for predicting volume respo...
Next Document:  Remifentanil patient-controlled analgesia effect-site target-controlled infusion compared with morph...