Performance of Semiautomatic Assessment of Carotid Artery Stenosis on CT Angiography: Clarification of Differences with Manual Assessment.
MedLine Citation:
PMID:  22194365     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND AND PURPOSE:Semiautomated methods for ICA stenosis measurements have the potential to reduce interobserver variability and to speed up its analysis. In this study, we estimate the precision and accuracy of a semiautomated measurement for carotid artery stenosis degree and identify and explain differences compared with the manual method.MATERIALS AND METHODS:In this retrospective study involving 90 patients, 2 observers determined the stenosis degree twice, with both the semiautomated and the manual method. Intra- and interobserver correlations were calculated for both methods. The accuracy was estimated by comparing average semiautomated with manual measurements. The semiautomated stenosis calculations were performed using either the minimal or maximal intersection at the reference site. Individual cases with large differences in measurement were retrospectively inspected by 3 observers.RESULTS:Intra- (R = 0.93, 0.96) and interobserver (R = 0.98) correlations for the semiautomated method were excellent and exceeded the manual performance correlations (R = 0.87, 0.86). The semiautomated measurements correlated well with the manual measurements (R = 0.87), with high specificity of 96% and lower sensitivity of 63%. Large differences were caused by misinterpretations of the semiautomated method associated with calcified plaques, resulting in overestimations of the minimal diameter, underestimation of stenosis degree, and incorrect centerlines. The effect of using the minimal diameter at the reference position resulted in a small, but significant, underestimation of the stenosis degree by the semiautomated method.CONCLUSIONS:The semiautomated method showed an excellent reproducibility and good correlation with manual measurements with a high specificity and lower sensitivity for detecting a significant stenosis. Erroneous semiautomatic stenosis measurements were associated with the presence of calcium.
Authors:
H A Marquering; P J Nederkoorn; L Smagge; H A Gratama van Andel; R van den Berg; C B Majoie
Related Documents :
18565415 - Carotid stenting: new devices on the horizon and beyond.
879275 - Effect of occlusion on large vessels. i. a study of the rat carotid artery.
7055425 - Real-time doppler spectrum analysis: predictive value in defining operable carotid arte...
15674835 - Evaluation of carotid artery wall thickness with high-resolution sonography in obstruct...
2106115 - The petrous carotid artery: anatomic relationships in skull base surgery.
7865395 - Femoral venous reflux abolished by greater saphenous vein stripping.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-12-22
Journal Detail:
Title:  AJNR. American journal of neuroradiology     Volume:  -     ISSN:  1936-959X     ISO Abbreviation:  -     Publication Date:  2011 Dec 
Date Detail:
Created Date:  2011-12-23     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8003708     Medline TA:  AJNR Am J Neuroradiol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Departments of Radiology, Biomedical Engineering and Physics, and Neurology, Academic Medical Center, Amsterdam, the Netherlands.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Biologic Imaging of Head and Neck Cancer: The Present and the Future.
Next Document:  3D Computerized Occlusion Rating of Embolized Experimental Aneurysms Using Noninvasive 1.5T MR Imagi...