Document Detail


Percutaneous Ablation of Renal Masses Measuring 3.0 cm and Smaller: Comparative Local Control and Complications After Radiofrequency Ablation and Cryoablation.
MedLine Citation:
PMID:  23345372     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
OBJECTIVE: The purpose of this article is to compare the efficacy and complication rates of percutaneous radiofrequency ablation (RFA) and cryoablation in the treatment of renal masses measuring 3.0 cm and smaller.
MATERIALS AND METHODS: A retrospective review was performed of 385 patients with 445 tumors measuring 3.0 cm or smaller treated with thermal ablation from 2000 through 2010. Two hundred fifty-six tumors in 222 patients were treated with RFA (mean [± SD] tumor size, 1.9 ± 0.5 cm), and 189 tumors in 163 patients were treated with cryoablation (mean tumor size, 2.3 ± 0.5 cm). Major complications and efficacy as measured by technical success and local tumor recurrence rates were recorded.
RESULTS: There were five (1.1%) technical failures, including one (0.4%) among tumors treated with RFA and four (2.1%) among tumors treated with cryoablation (p = 0.17). Of the 218 tumors treated with RFA and with follow-up beyond 3 months, seven (3.2%) developed local tumor recurrence, at a mean of 2.8 years after treatment (range, 1.2-4.1 years). Of the 145 tumors treated with cryoablation and with follow-up beyond 3 months, four (2.8%) developed local tumor recurrence at a mean of 0.9 years after treatment (range, 0.3-1.6 years). For biopsy-proven renal cell carcinoma, estimated local recurrence-free survival rates at 1, 3, and 5 years after RFA were 100%, 98.1%, and 98.1%, respectively, compared with 97.3%, 90.6%, and 90.6%, respectively, after cryoablation (p = 0.09). Major complications occurred after 4.3% (10/232) of RFAs and 4.5% (8/176) of cryoablation procedures (p = 0.91).
CONCLUSION: RFA and cryoablation are both effective in the treatment of renal masses measuring 3 cm or smaller. Major complications with either procedure are infrequent.
Authors:
Thomas D Atwell; Grant D Schmit; Stephen A Boorjian; Jay Mandrekar; A Nicholas Kurup; Adam J Weisbrod; George K Chow; Bradley C Leibovich; Matthew R Callstrom; David E Patterson; Christine M Lohse; R Houston Thompson
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  AJR. American journal of roentgenology     Volume:  200     ISSN:  1546-3141     ISO Abbreviation:  AJR Am J Roentgenol     Publication Date:  2013 Feb 
Date Detail:
Created Date:  2013-01-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7708173     Medline TA:  AJR Am J Roentgenol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  461-6     Citation Subset:  AIM; IM    
Affiliation:
Department of Diagnostic Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55902.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Endoleak Detection After Endovascular Repair of Thoracic Aortic Aneurysm Using Dual-Source Dual-Ener...
Next Document:  Radiology on the Africa Mercy, the largest private floating hospital ship in the world.