Abstract/OtherAbstract:
Audible cardiac murmurs are uncommon and may indicate severe native valve dysfunction. In six patients with bioprosthetic mitral valves audible honking systolic murmurs suddenly developed. Doppler echocardiography showed characteristic striated regurgitant signals. At operation each prosthesis had torn cusps. New audible murmurs and striated Doppler signals originating from mitral bioprosthetic valves are indicators of cusp tears. Recognition of this is important because early detection of prosthetic valve dysfunction may improve subsequent surgical outcome.
Authors:
M Errington; P Bloomfield; I R Starkey; T R Shaw
Related Documents :
485628 - Dynamic behavior of prosthetic aortic tissue valves as viewed by high-speed cinematogra...
12479288 - Chronic, preclinical assessment of the medtronic advantage aortic valve prosthesis.
24337228 - Numerical simulation of vertebral artery stenosis treated with different stents.
8277758 - Comparative study of the function of the abiomed polyurethane heart valve for use in le...
6421168 - Amyloid deposits in bioprosthetic cardiac valves after long-term implantation in man. a...
22621718 - The year in review: surgical revascularization of coronary artery disease-2011.
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  British heart journal     Volume:  64     ISSN:  0007-0769     ISO Abbreviation:  Br Heart J     Publication Date:  1990 Dec 
Date Detail:
Created Date:  1991-02-25     Completed Date:  1991-02-25     Revised Date:  2009-11-18    
Medline Journal Info:
Nlm Unique ID:  0370634     Medline TA:  Br Heart J     Country:  ENGLAND    
Other Details:
Languages:  eng     Pagination:  393-4     Citation Subset:  AIM; IM    
Affiliation:
Royal Infirmary, Edinburgh.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Bioprosthesis*
Echocardiography, Doppler
Female
Heart Murmurs / etiology*,  ultrasonography
Heart Valve Prosthesis*
Humans
Male
Middle Aged
Mitral Valve / ultrasonography
Prosthesis Failure
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Circadian variation of heart rate is affected by environment: a study of continuous electrocardiogra...
Next Document:  A new method of haemodynamic assessment of mitral stenosis in atrial fibrillation: construction of a...