Document Detail


Patient satisfaction with the external equipment of implantable left ventricular assist devices.
MedLine Citation:
PMID:  20883391     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Patient satisfaction with left ventricular assist device (LVAD) external equipment has not yet been reported. We aimed to evaluate the quality of two different systems based on patients' perspective and its interrelationship with quality of life. Differential assessment of the HeartMate II axial flow pump (n = 17; Thoratec, Pleasanton, CA, USA) and the HVAD centrifugal pump (n = 10; HeartWare, Inc., Miramar, FL, USA) was obtained from 27 outpatients by a questionnaire 2 months to 2.9 years after device implantation. In addition, a health-related quality of life questionnaire (Short Form-36 [SF-36]) was completed. Overall patients' satisfaction was high. Severe limitations were attributed to the loudness of the power base unit in HeartMate II patients (P = 0.00), and HVAD patients were dissatisfied by the length of the driveline (P = 0.02). Between HVAD and HeartMate II patients, no significant differences in the quality of life (assessed by SF-36) were reported. While the overall satisfaction of outpatients on LVAD support was high, differences between the systems were found. Patients' perspectives may have an important impact on future modification of external components. Ultimately, this may also contribute to an improvement in the quality of life of chronic LVAD patients.
Authors:
Anna L Meyer; Christiane Kugler; Doris Malehsa; Axel Haverich; Martin Strueber
Publication Detail:
Type:  Comparative Study; Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Artificial organs     Volume:  34     ISSN:  1525-1594     ISO Abbreviation:  Artif Organs     Publication Date:  2010 Sep 
Date Detail:
Created Date:  2010-10-01     Completed Date:  2011-01-13     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7802778     Medline TA:  Artif Organs     Country:  United States    
Other Details:
Languages:  eng     Pagination:  721-5     Citation Subset:  IM    
Copyright Information:
© 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Affiliation:
Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adaptation, Psychological
Adult
Analysis of Variance
Female
Germany
Heart Failure / psychology,  therapy*
Heart-Assist Devices*
Humans
Male
Middle Aged
Patient Satisfaction*
Prosthesis Design
Quality of Life*
Questionnaires
Time Factors
Treatment Outcome
Young Adult

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Atrial versus ventricular cannulation for a rotary ventricular assist device.
Next Document:  Fully autonomous preload-sensitive control of implantable rotary blood pumps.