Patient radiation dose at CT urography and conventional urography.
MedLine Citation:
PMID:  15220498     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
PURPOSE: To measure and compare patient radiation dose from computed tomographic (CT) urography and conventional urography and to compare these doses with dose estimates determined from phantom measurements. MATERIALS AND METHODS: Patient skin doses were determined by placing a thermoluminescent dosimeter (TLD) strip (six TLD chips) on the abdomen of eight patients examined with CT urography and 11 patients examined with conventional urography. CT urography group consisted of two women and six men (mean age, 55.5 years), and conventional urography group consisted of six women and five men (mean age, 58.9 years). CT urography protocol included three volumetric acquisitions of the abdomen and pelvis. Conventional urography protocol consisted of acquisition of several images involving full nephrotomography and oblique projections. Mean and SD of measured patient doses were compared with corresponding calculated doses and with dose measured on a Lucite pelvic-torso phantom. Correlation coefficient (R(2)) was calculated to compare measured and calculated skin doses for conventional urography examination, and two-tailed P value significance test was used to evaluate variation in effective dose with patient size. Radiation risk was calculated from effective dose estimates. RESULTS: Mean patient skin doses for CT urography measured with TLD strips and calculated from phantom data (CT dose index) were 56.3 mGy +/- 11.5 and 54.6 mGy +/- 4.1, respectively. Mean patient skin doses for conventional urography measured with TLD strips and calculated as entrance skin dose were 151 mGy +/- 90 and 145 mGy +/- 76, respectively. Correlation coefficient between measured and calculated skin doses for conventional urography examinations was 0.95. Mean effective dose estimates for CT urography and conventional urography were 14.8 mSv +/- 90.0 and 9.7 mSv +/- 3.0, respectively. Mean effective doses estimated for the pelvic-torso phantom were 15.9 mSv (CT urography) and 7.8 mSv (conventional urography). CONCLUSION: Standard protocol for CT urography led to higher mean effective dose, approximately 1.5 times the radiation risk for conventional urography. Patient dose estimates should be taken into consideration when imaging protocols are established for CT urography.
Authors:
Richard D Nawfel; Philip F Judy; A Robert Schleipman; Stuart G Silverman
Related Documents :
10721318 - Skin sparing in interventional radiology: the effect of copper filtration.
19741358 - Calculation of indoor effective dose factors in ornl phantoms series due to natural rad...
2739618 - Interface dosimetry for i-125 sources.
12349928 - Comparison of four methods for assessing patient effective dose from radiological exami...
7935028 - Effects of 2 years of hormone replacement upon bone mass, serum lipids and lipoproteins.
21063048 - Current malaria management: guideline 2009.
Publication Detail:
Type:  Comparative Study; Journal Article    
Journal Detail:
Title:  Radiology     Volume:  232     ISSN:  0033-8419     ISO Abbreviation:  Radiology     Publication Date:  2004 Jul 
Date Detail:
Created Date:  2004-06-28     Completed Date:  2004-07-29     Revised Date:  2006-11-15    
Medline Journal Info:
Nlm Unique ID:  0401260     Medline TA:  Radiology     Country:  United States    
Other Details:
Languages:  eng     Pagination:  126-32     Citation Subset:  AIM; IM    
Copyright Information:
Copyright RSNA, 2004
Affiliation:
Department of Radiology, Brigham and Women's Hospital, 75 Francis St, Boston, MA 02115, USA. nawfel@bwh.harvard.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Female
Humans
Kidney / radiography
Male
Middle Aged
Pelvis / radiography
Phantoms, Imaging
Radiation Dosage
Skin / radiation effects*
Thermoluminescent Dosimetry
Tomography, X-Ray Computed*
Urography*
Comments/Corrections
Comment In:
J Urol. 2005 Mar;173(3):923-4   [PMID:  15711330 ]

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Nationwide Evaluation of X-ray Trends survey of abdomen and lumbosacral spine radiography.
Next Document:  Ethiodized oil-ethanol capillary embolization in rabbit kidneys: temporal histopathologic findings.