Patellar tracking during the gait cycle.
MedLine Citation:
PMID:  22184156     Owner:  NLM     Status:  In-Data-Review    
Abstract/OtherAbstract:
PURPOSE. To assess normal patellar tracking during walking using the 9-camera infrared system. METHODS. Four men and 6 women aged 25 to 33 (mean, 29) years each performed 16 walking trials on one occasion. They had prominent patellae with minimal soft tissues (minimising skin artefacts), and their knees and lower limbs were normal and symmetrical. 12 retro-reflective markers (2.5 cm in diameter) were taped to anatomic landmarks of the lower body. Two additional markers (1.4 cm in diameter) were first placed on the medial and lateral points and then proximal and distal points of the patella. Patellar motion relative to the centre of the knee joint was defined as angles between the centre of the knee joint and the 2 sets of patellar markers (medial-lateral and proximal-distal). The mean, maximum, and minimum values of these angles in a standing position were recorded, as was patellar tracking during walking. The X, Y, and Z coordinates for each marker were smoothed out throughout the capturing time. A single gait cycle per trial was chosen for analysis. RESULTS. During walking, the centre of the knee joint and the patella did not move in unison, and the extent of separation was subject dependent. In 70% of the participants, the maximum angle between the centre of the knee joint and each set of markers occurred in the swing phase (0-43%) of the gait cycle. When analysing both sets of markers together, the percentage of participants became 60%. The extent of knee flexion was subject dependent. There was more medial-lateral motion (shift) of the patella than proximal-distal (tilt) motion during the gait cycle. These indicated that the maximum amount of patellar shift and tilt occurred in the swing and early stance phases of the gait cycle and that abnormal patellar motion can be detected if excessive shift or tilt occurs outside of these phases. CONCLUSION. Patella mal-tracking could be attributed to the position of the lower body segments rather than the absorption or generation of forces.
Authors:
G Abbas; C Diss
Related Documents :
19309016 - Adapted liquid crystal display backlighting unit for densitometry of stained polyacryla...
18945476 - Functional properties of dom in a stream draining blanket peat.
426046 - Micro-light guides: a new method for measuring tissue fluorescence and reflectance.
23117096 - Forefoot angle determines duration and amplitude of pronation during walking.
23223076 - A novel soft biomimetic microrobot with two motion attitudes.
2128016 - Bactericidal effectiveness of modulated uv light.
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Journal of orthopaedic surgery (Hong Kong)     Volume:  19     ISSN:  1022-5536     ISO Abbreviation:  J Orthop Surg (Hong Kong)     Publication Date:  2011 Dec 
Date Detail:
Created Date:  2011-12-20     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9440382     Medline TA:  J Orthop Surg (Hong Kong)     Country:  China    
Other Details:
Languages:  eng     Pagination:  288-91     Citation Subset:  IM    
Affiliation:
Department of Trauma and Orthopaedics, Royal Cornwall Hospital, Cornwall, England.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Predictors of length of hospital stay after total hip replacement.
Next Document:  Displaced tibial intercondylar eminence fractures.