Document Detail


Passive flow-rate regulators using pressure-dependent autonomous deflection of parallel membrane valves.
MedLine Citation:
PMID:  19568677     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
We present passive flow-rate regulators using an autonomous deflection of parallel membrane valves, capable to maintain a constant flow-rate at varying inlet pressure supplied from micropumps. The previous passive flow-rate regulators are difficult to integrate with micropumps, not only because of the complex multi-layer structures, but also because of the high threshold inlet pressure required for flow-rate regulation. In this study, we present passive flow-rate regulators using parallel membrane valves, capable of achieving flow-rate regulation function at the minimum threshold inlet pressure as low as 15 kPa with simple structure formed by a single mask process. The parallel membranes in a flow-rate regulator are designed to deflect and adjust flow resistance autonomously according to the inlet pressure, thus maintaining a constant flow-rate independent of the inlet pressure variation. We designed the four different prototypes of W20, W30, W40, and W50, having parallel membrane widths of 20, 30, 40 and 50 microm, respectively. We estimated the flow-rate based on both analytical and numerical models. In an experimental study, we observed the deformation of parallel membranes and the flow-rate depending on the inlet pressure. The fabricated prototypes achieved the constant flow-rate of 6.09 +/- 0.32 microl s(-1) (W20 fabricated by 10 : 1 PDMS (PolyDiMethylSiloxane)) over an inlet pressure of 20 kPa. We also observed that prototypes fabricated by 20 : 1 PDMS, having lower Young's modulus than normal 10 : 1 PDMS, showed a lower threshold pressure and higher regulated flow-rate than prototypes fabricated by 10 : 1 PDMS. W40 fabricated by 20 : 1 PDMS showed a constant flow-rate of 14.53 +/- 0.51 microl s(-1) over inlet pressure of 15 kPa. The present passive flow-rate regulators have strong potential for applications in integrated microfluidic systems.
Authors:
Il Doh; Young-Ho Cho
Related Documents :
12685137 - Influencing the heart rate of rats with weak external mechanical stimulation.
4033097 - Transient interactions between blood pressure, respiration and heart rate in man.
6849777 - Contribution of the vagus to the haemodynamic responses following intravenous boluses o...
1505147 - Differing effect of atropine on heart rate in chinese and white subjects.
19653517 - Cardiovascular effects of lumbar epidural anaesthesia in isoflurane-anaesthetised pigs ...
12228847 - Calcium channel blockade in combination with angiotensin-converting enzyme inhibition o...
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't     Date:  2009-04-08
Journal Detail:
Title:  Lab on a chip     Volume:  9     ISSN:  1473-0197     ISO Abbreviation:  Lab Chip     Publication Date:  2009 Jul 
Date Detail:
Created Date:  2009-07-01     Completed Date:  2009-08-18     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101128948     Medline TA:  Lab Chip     Country:  England    
Other Details:
Languages:  eng     Pagination:  2070-5     Citation Subset:  IM    
Affiliation:
Digital Nanolocomotion Center, Department of Bio and Brain Engineering, KAIST, Yuseong-gu, Daejeon, Republic of Korea.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Equipment Design
Membranes, Artificial*
Microfluidics / instrumentation,  methods*
Microtechnology
Pressure*
Chemical
Reg. No./Substance:
0/Membranes, Artificial

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Free jet micromixer to study fast chemical reactions by small angle X-ray scattering.
Next Document:  Demonstration of an integrated electroactive polymer actuator on a microfluidic electrophoresis devi...