Parameter selection in permutation entropy for an electroencephalographic measure of isoflurane anesthetic drug effect.
MedLine Citation:
PMID:  23264067     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
The permutation entropy (PE) of the electroencephalographic (EEG) signals has been proposed as a robust measure of anesthetic drug effect. The calculation of PE involves the somewhat arbitrary selection of embedding dimension (m) and lag (τ) parameters. Previous studies of PE include the analysis of EEG signals under sevoflurane or propofol anesthesia, where different parameter settings were determined using a number of different criteria. In this study we choose parameter values based on the quantitative performance, to quantify the effect of a wide range of concentrations of isoflurane on the EEG. We analyzed a set of previously published EEG data, obtained from 29 patients who underwent elective abdominal surgery under isoflurane general anesthesia combined with epidural anesthesia. PE indices using a range of different parameter settings (m = 3-7, τ = 1-5) were calculated. These indices were evaluated as regards: the correlation coefficient (r) with isoflurane end-tidal concentration, the relationship with isoflurane effect-site concentration assessed by the coefficient of determination (R (2)) of the pharmacokinetic-pharmacodynamic models, and the prediction probability (P(K)). The embedding dimension (m) and lag (τ) have significant effect on the r values (Two-way repeated-measures ANOVA, p < 0.001). The proposed new permutation entropy index (NPEI) [a combination of PE(m = 3, τ = 2) and PE(m = 3, τ = 3)] performed best among all the parameter combinations, with r = 0.89(0.83-0.94), R (2) = 0.82(0.76-0.87), and P(K) = 0.80 (0.76-0.85). Further comparison with previously suggested PE measures, as well as other unrelated EEG measures, indicates the superiority of the NPEI. The PE can be utilized to indicate the dynamical changes of EEG signals under isoflurane anesthesia. In this study, the NPEI measure that combines the PE with m = 3, τ = 2 and that with m = 3, τ = 3 is optimal.
Authors:
Duan Li; Zhenhu Liang; Yinghua Wang; Satoshi Hagihira; Jamie W Sleigh; Xiaoli Li
Related Documents :
1642767 - Factors involved in burn mortality: a multivariate statistical approach based on discri...
17688677 - Modeling longitudinal data in acute illness.
24737957 - A new mixed element method for a class of time-fractional partial differential equations.
20682037 - The impact of delirium on the prediction of in-hospital mortality in intensive care pat...
10357647 - Graded autocatalysis replication domain (gard): kinetic analysis of self-replication in...
24444967 - Physicochemical parameters and sensory properties of honeys from buenos aires region.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-12-22
Journal Detail:
Title:  Journal of clinical monitoring and computing     Volume:  -     ISSN:  1573-2614     ISO Abbreviation:  J Clin Monit Comput     Publication Date:  2012 Dec 
Date Detail:
Created Date:  2012-12-24     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  9806357     Medline TA:  J Clin Monit Comput     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Institute of Information Science and Engineering, Yanshan University, Qinhuangdao, 066004, China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Sensitive immunodetection of radiotoxicity after iodine-131 therapy for thyroid cancer using ?-H2AX ...
Next Document:  Outcome impact of goal directed fluid therapy during high risk abdominal surgery in low to moderate ...