Document Detail


The Pacing Therapies for Congestive Heart Failure (PATH-CHF) study: rationale, design, and endpoints of a prospective randomized multicenter study.
MedLine Citation:
PMID:  10089855     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
In conjunction with pharmacologic therapy, pacing has been proposed as a potential treatment to decrease symptoms in patients with moderate-to-severe congestive heart failure (CHF). Uncontrolled studies of pacing therapy for CHF dealing with different pacing sites, modes of pacing, and atrioventricular delays have reported mixed outcomes. The Pacing Therapies in Congestive Heart Failure (PATH-CHF) study is a single-blind, randomized, crossover, controlled trial designed to evaluate the effects of pacing on acute hemodynamic function and to assess chronic clinical benefit in patients with moderate-to-severe CHF. The effect of pacing on oxygen consumption at peak exercise and at anaerobic threshold during cardiopulmonary exercise tests, and on 6-minute walk distance, have been selected as primary endpoints of the study. Secondary endpoints of the trial were changes in New York Heart Association (NYHA) functional class, quality-of-life as assessed by the Minnesota Living with Heart Failure questionnaire, and hospitalization frequency. Finally, changes in ejection fraction, cardiac output, and filling pattern were assessed by echocardiography. The trial was planned to include 53 patients from 7 centers in Europe over a period of 3 years. The study was divided into 2 parts: acute testing and chronic follow-up. The acute study, performed during the pacemaker implantation, involved extensive testing using a custom-designed computer (FLEXSTIM) and a unique burst pacing protocol (FLEXSTIM protocol) to determine the best ventricular pacing sites and the most appropriate atrioventricular delays. The chronic phase consisted of a crossover study designed to test in each patient the best univentricular pacing site and biventricular pacing as assessed by the acute hemodynamic study. The study started with the first implant in 1995 and has, to date, included 42 patients. The study is expected to be completed by the end of 1998. The results of a first interim analysis showed trends toward improvement in all primary and secondary endpoints during the pacing periods compared with no pacing.
Authors:
A Auricchio; C Stellbrink; S Sack; M Block; J Vogt; P Bakker; P Mortensen; H Klein
Related Documents :
20440045 - Ventricular pacing redundancy to prevent loss of capture: a fail-safe for pacemaker-dep...
1548955 - The next 5 years in cardiac pacemakers: a preview.
9604235 - An optimized av delay algorithm for patients with intermittent atrioventricular conduct...
10987605 - Biventricular pacing diminishes the need for implantable cardioverter defibrillator the...
3953365 - "acute pericarditis": myocardial enzyme release as evidence for myocarditis.
2272135 - Acute anterior myocardial infarction: streptokinase prevents ventricular thrombosis ind...
Publication Detail:
Type:  Clinical Trial; Comparative Study; Journal Article; Multicenter Study; Randomized Controlled Trial; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  The American journal of cardiology     Volume:  83     ISSN:  0002-9149     ISO Abbreviation:  Am. J. Cardiol.     Publication Date:  1999 Mar 
Date Detail:
Created Date:  1999-04-07     Completed Date:  1999-04-07     Revised Date:  2007-11-15    
Medline Journal Info:
Nlm Unique ID:  0207277     Medline TA:  Am J Cardiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  130D-135D     Citation Subset:  AIM; IM    
Affiliation:
Department of Cardiology, University Hospital, Magdeburg, Germany.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Aged
Cross-Over Studies
Electrocardiography, Ambulatory / instrumentation
Exercise Test / instrumentation
Female
Heart Atria / physiopathology
Heart Failure / physiopathology,  therapy*
Heart Ventricles / physiopathology
Hemodynamics / physiology
Humans
Male
Middle Aged
Pacemaker, Artificial*
Prospective Studies
Signal Processing, Computer-Assisted / instrumentation
Stroke Volume / physiology
Treatment Outcome