Document Detail


Pacemaker-mediated polymorphic ventricular tachycardia.
MedLine Citation:
PMID:  9793097     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
A patient with refractory bradycardia dependent polymorphic ventricular tachycardia (PMVT) underwent permanent pacemaker placement for suppression of her arrhythmia. Following implant, the patient had recurrent PMVT. Interrogation of the device revealed a factory programmed feature (+ PVARP on PVC) designed to prevent pacemaker-mediated tachycardia that led to cycle length variability and subsequent arrhythmia recurrence. This feature was deactivated and the patients' arrhythmia did not recur.
Authors:
D S Goldman; P A Levine
Related Documents :
15271027 - Magnetic resonance imaging-based biventricular pacemaker upgrade.
1911297 - Skin susceptibility in uninvolved skin of hand eczema patients and healthy controls.
2669707 - The deviation of the body's sway center with galvanic stimulation.
25258637 - In-hospital outcomes after primary percutaneous coronary intervention according to left...
11724437 - Sudden death from myocardial contusion following an isolated blunt force trauma to the ...
6528267 - Myocardial catecholamines following cold cardioplegic arrest during open-heart surgery.
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Pacing and clinical electrophysiology : PACE     Volume:  21     ISSN:  0147-8389     ISO Abbreviation:  Pacing Clin Electrophysiol     Publication Date:  1998 Oct 
Date Detail:
Created Date:  1998-12-21     Completed Date:  1998-12-21     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  7803944     Medline TA:  Pacing Clin Electrophysiol     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  1993-5     Citation Subset:  IM    
Affiliation:
Division of Cardiology, University of Florida, Jacksonville, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Algorithms
Electrocardiography
Equipment Design
Female
Humans
Pacemaker, Artificial / adverse effects*
Recurrence
Tachycardia, Ventricular / etiology*,  therapy*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Pharmacological stress testing of the His-Purkinje system in patients with bifascicular block.
Next Document:  Electromagnetic interference from a muscle stimulation device causing discharge of an implantable ca...