Pacemaker-induced change in prosthetic valvular sounds.
MedLine Citation:
PMID:  1261315     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Variable intensity and timing of valvular sounds were noted in two patients with permanent pacemakers and prosthetic valves. In the first patient, who had a mitral and a tricuspid prosthesis, valvular opening sounds became widely separated with a change from nodal to ventricular paced rhythm. In a second patient, who had a mitral prosthesis in sinus rhythm with first-degree atrioventricular block, a very quiet closing sound increased markedly in intensity with the onset of ventricular pacing. The mechanism for these changes is described using a technique which at brief intervals throughout the cardiac cycle permitted documentation of simultaneously recorded phonocardiogram, electrocardiogram, and pulse tracings with a visible image of the prosthesis. In the usual patient with a prosthetic valve auscultatory changes should arouse a suspicion of malfunction; however, in the relatively uncommon patient with a prosthesis and an artificial pacemaker, it should be recognized that auscultatory changes may well have a physiologic explanation.
Authors:
D F Brown; G Prescott
Related Documents :
1625735 - Implications of third heart sounds in patients with valvular heart disease. the veteran...
16727325 - Zona-penetration in vitro test for evaluating boar sperm fertility.
24604505 - Short-coupled variant of torsade de pointes - an important cause of syncope and sudden ...
23705565 - Quinidine for the management of electrical storm in an old patient with brugada syndrom...
25155805 - Role of speckle tracking echocardiography in the assessment of post-repair left ventric...
16717465 - Impact of early tirofiban administration on myocardial salvage in patients with acute m...
Publication Detail:
Type:  Case Reports; Journal Article    
Journal Detail:
Title:  Chest     Volume:  69     ISSN:  0012-3692     ISO Abbreviation:  Chest     Publication Date:  1976 Apr 
Date Detail:
Created Date:  1976-07-06     Completed Date:  1976-07-06     Revised Date:  2004-11-17    
Medline Journal Info:
Nlm Unique ID:  0231335     Medline TA:  Chest     Country:  UNITED STATES    
Other Details:
Languages:  eng     Pagination:  490-4     Citation Subset:  AIM; IM    
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adult
Electrocardiography
Female
Heart Auscultation*
Heart Sounds*
Heart Valve Prosthesis*
Humans
Male
Middle Aged
Mitral Valve / surgery
Pacemaker, Artificial*
Phonocardiography
Tricuspid Valve / surgery

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Effect of exercise on left ventricular ejection time in patients with prolapsing mitral leaflet synd...
Next Document:  Focal myocytolysis mimicking the electrocardiographic pattern of transmural anteroseptal myocardial ...