Document Detail


Overdrive pacing for endovascular repair of an aortic arch aneurysm.
MedLine Citation:
PMID:  19921369     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The endovascular treatment of aortic arch aneurysms is a relatively new technique and is associated with significant surgical and anesthetic challenges. We report a case of a 77-year-old patient with an aortic arch aneurysm at the level of the isthmus, measuring 4.9 x 6.5 cm. The aneurysm involved the origin of the left subclavian and vertebral arteries. The arch was of the bovine type and the left vertebral artery came directly off the aorta. The patient underwent an uneventful open left carotid-to-subclavian bypass several days before the aortic repair. During the endovascular surgery, a stent-graft was deployed just distal to the innominate trunk. Endoleak was noted at the inferior aspect of the stent-graft, which failed to seal with placement of an extension stent-graft. The surgeon then chose to employ a Palmaz stent, to seal the endoleak. Balloon expansion in the ascending aorta was required in order to properly seat the Palmaz stent. Overdrive pacing at a rate of 220 beats min(-1), which lowered the systolic blood pressure (SBP) to 40s mmHg was used during this process after connecting the patient to a Zoll defibrillator with external pads. The Palmaz stent was successfully deployed at the proximal end of the previously deployed stent-graft, using a Tyshak balloon. The patient reverted to normal sinus rhythm with no evidence of ischemia at the conclusion of the overdrive pacing. No endoleak was appreciated after the Palmaz stent was placed.
Authors:
Sherif S Zaky; Theodore Marks
Related Documents :
7497509 - A novel approach to the placement of palmaz-schatz biliary stents in saphenous vein gra...
10787209 - Assessment of a polyester-covered nitinol stent in an atherosclerotic swine model.
10388859 - Expandable metal stents for benign esophageal obstruction.
15900549 - Emergency stent graft deployment for acute aortic rupture following primary stenting fo...
20798369 - Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospec...
16520179 - Inflammatory responses involving tumor necrosis factor receptor-associated factor 6 con...
14529159 - Pathological lesions causing pulmonary hypertension after closure of a ventricular sept...
21352499 - Coding polymorphisms in the genes of the alternative complement pathway and abdominal a...
9211599 - Bland-white-garland syndrome in an adult. case report and review of diagnostic and pred...
Publication Detail:
Type:  Case Reports; Journal Article     Date:  2009-11-18
Journal Detail:
Title:  Journal of anesthesia     Volume:  23     ISSN:  1438-8359     ISO Abbreviation:  J Anesth     Publication Date:  2009  
Date Detail:
Created Date:  2009-11-20     Completed Date:  2010-01-26     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8905667     Medline TA:  J Anesth     Country:  Japan    
Other Details:
Languages:  eng     Pagination:  576-8     Citation Subset:  IM    
Affiliation:
Department of General Anesthesiology, Anesthesia Institute, Cleveland Clinic, Cleveland, OH 44195, USA.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Aged
Angioplasty, Transluminal, Percutaneous Coronary
Aorta, Thoracic / surgery*
Aortic Aneurysm / surgery*
Cardiac Pacing, Artificial
Cardiac Surgical Procedures*
Coronary Artery Bypass
Hemodynamics / physiology
Humans
Male
Perioperative Care
Stents
Tomography, X-Ray Computed

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Perioperative management of a neonate with Cantrell syndrome.
Next Document:  Anesthetic management of renal transplantation in a patient with familial dysautonomia.