Document Detail

Outcomes of the different types of total knee arthroplasty with the identical femoral geometry.
Jump to Full Text
MedLine Citation:
PMID:  23269959     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
PURPOSE: There are controversies around the role of the posterior cruciate ligament and the effect of design modifications for high flexion in total knee arthroplasty (TKA). So, we compared the clinical outcomes of the cruciate retaining (CR), posterior stabilized (PS), and high flexion posterior stabilized (F-PS) designs in TKA with identical femoral geometry.
MATERIALS AND METHODS: One hundred seventy nine knees with 3 different types of prostheses after a minimum 5-year follow-up were enrolled in this retrospective study: 45 with CR, 40 with PS and 94 with F-PS. The mean ages of these groups were 65.7, 67.2, and 67.5, and the mean durations of follow-up were 8.1, 8.0, and 6.8 years, respectively. We compared the range of motion, functional outcomes, and radiographic measurements at the 2-year follow-up and last follow-up.
RESULTS: The maximal flexion angle was significantly lower in the CR group than the F-PS group at the 2-year follow-up. However, there was no significant difference at the last follow-up. Functional outcomes and survival rate of the three groups were similar at the last follow-up.
CONCLUSIONS: Three different types of TKAs (CR, PS and F-PS) with identical femoral geometry showed similar mid-term outcomes with regard to the range of motion, functional outcomes and survival rate.
Authors:
Sang Min Lee; Sang Cheol Seong; Sahnghoon Lee; Won Chul Choi; Myung Chul Lee
Related Documents :
8905889 - Treatment of recurrent hemoptysis in a child with cystic fibrosis by repeated bronchial...
1081529 - Storage of polyvinylpyrrolidone mimicking a congenital mucolipid storage disease in a p...
10382079 - A pilot efficacy study with a single-rod contraceptive implant (implanon) in 200 indone...
21756859 - King lt-d use by urban basic life support first responders as the primary airway device...
11474999 - Treatment of watermelon stomach (gave syndrome) by means of endoscopic argon plasma coa...
14529929 - Rapid correction of prothrombin time after low-dose recombinant factor viia in patients...
19408329 - Comparison of the effects of 1,25 dihydroxyvitamin d and 25 hydroxyvitamin d on bone pa...
24549209 - The effect of new method of suspension on quality of life, satisfaction, and suspension...
23295449 - Treatment of ascending aortic aneurysms using different surgical techniques: a single-c...
Publication Detail:
Type:  Journal Article     Date:  2012-11-29
Journal Detail:
Title:  Knee surgery & related research     Volume:  24     ISSN:  2234-0726     ISO Abbreviation:  Knee Surg Relat Res     Publication Date:  2012 Dec 
Date Detail:
Created Date:  2012-12-27     Completed Date:  2012-12-28     Revised Date:  2013-05-30    
Medline Journal Info:
Nlm Unique ID:  101575761     Medline TA:  Knee Surg Relat Res     Country:  Korea (South)    
Other Details:
Languages:  eng     Pagination:  214-20     Citation Subset:  -    
Affiliation:
Department of Orthopedic Surgery, Eulji University College of Medicine, Daejeon, Korea.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Comments/Corrections

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine

Full Text
Journal Information
Journal ID (nlm-ta): Knee Surg Relat Res
Journal ID (iso-abbrev): Knee Surg Relat Res
Journal ID (publisher-id): KSRR
ISSN: 2234-0726
ISSN: 2234-2451
Publisher: The Korean Knee Society
Article Information
Download PDF
Copyright © 2012. The Korean Knee Society
open-access:
Received Day: 01 Month: 4 Year: 2012
Revision Received Day: 01 Month: 8 Year: 2012
Accepted Day: 17 Month: 8 Year: 2012
Print publication date: Month: 12 Year: 2012
Electronic publication date: Day: 29 Month: 11 Year: 2012
Volume: 24 Issue: 4
First Page: 214 Last Page: 220
PubMed Id: 23269959
ID: 3526758
DOI: 10.5792/ksrr.2012.24.4.214

Outcomes of the Different Types of Total Knee Arthroplasty with the Identical Femoral Geometry
Sang Min Lee, MD1
Sang Cheol Seong, MD, PhD2
Sahnghoon Lee, MD, PhD2
Won Chul Choi, MD3
Myung Chul Lee, MD, PhD2
1Department of Orthopedic Surgery, Eulji University College of Medicine, Daejeon, Korea.
2Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea.
3Department of Orthopedic Surgery, CHA Bundang Medical Center, CHA University, Seongnam, Korea.
Correspondence: Correspondence to: Myung Chul Lee, MD. Department of Orthopedic Surgery, Seoul National University College of Medicine, 101 Daehang-ro, Jongno-gu, Seoul 110-744, Korea. Tel: +82-2-2072-3212, Fax: +82-2-764-2718, leemc@snu.ac.kr

Introduction

Total knee arthroplasty (TKA) is a successful procedure for pain relief and functional restoration in patients with advanced osteoarthritis. Despite its success, a significant portion of patients are dissatisfied with their replaced knees because of their higher expectations on the function, such as high flexion activities1-3). Therefore, implant manufacturers have introduced many modifications to the prosthesis design for a better outcome. Nevertheless, some of these changes, including the handling of the posterior cruciate ligament and the design modifications for high flexion, are still controversial around the clinical outcomes and longevity4-8).

Surgeons with a preference for cruciate retaining (CR) knees set a high value on the function of the posterior cruciate ligament (PCL). They believe that the PCL has a beneficial effect on femoral rollback, quadriceps efficiency, joint stability and proprioception9,10). On the other hand, other surgeons who favor posterior stabilized (PS) knees have doubts about the function of the remaining PCL in CR knees11). Recently, increasing attention has been on whether the PS knee is superior to CR knee in the range of motion4,5).

Since the late 1990s, many implant manufacturers have made modifications to conventional prostheses designs to improve the maximal knee flexion. The design changes for high flexion had been in the polyethylene insert geometry, posterior femoral condylar offset, cam/post engagement, or a combination of these12-15). Nevertheless, it is unclear whether these design modifications improve the range of motion and clinical outcomes6-8,14,16). The high flexion implants used in the current study has a relaxed posterior slope of the polyethylene insert, compared to the conventional PS implant. This change in polyethylene insert geometry results in a reduced femoral rise, improved collateral ligament function in deep flexion, and reduced torsional constraint that requires less torque for rotation12). Although a high flexion design is theoretically superior to its conventional design, there is a controversy about whether a high flexion design facilitates greater knee flexion12,15). In addition, there are still concerns regarding whether this change of polyethylene insert affects the knee functions or longevity of replaced knees.

The purpose of this study was to compare the clinical outcomes of CR, PS, and high flexion PS prostheses having identical femoral component geometry. We hypothesized that retaining or substituting PCL and the change of polyethylene insert geometry for high flexion did not make a difference to the clinical outcomes of TKA.


Materials and Methods

This study was approved by our institutional review board. The data of 164 patients who underwent 225 primary total knee arthroplasties for primary osteoarthritis using the Scorpio total knee system (Stryker Orthopaedics, Mahwah, NJ, USA) between January 1999, and December 2004, were reviewed retrospectively: 57 knees with the Scorpio CR implants, 50 knees with the Scorpio PS implants, and 118 knees with the Scorpio Flex PS (F-PS) implants (Fig. 1). We included only primary osteoarthritic knees and there was no post-traumatic osteoarthritic knees, rheumatoid knees, stiff knees (range of knee motion, <60°) and severely deformed knees (tibiofemoral angle, >varus 20°). Implant selection was chronologically done in order of the prostheses development and launching. Twenty eight patients (37 knees) dropped out due to follow-up loss or death before the minimum follow-up of 5 years. In addition, four patients (5 knees) were excluded because of concurrent disease that could seriously affect the knee function such as an intracerebral hemorrhage, severe cerebral infarct and severe dementia. Another four knees were revised due to aseptic loosening or prosthesis infection before the 5-year follow-up. Aseptic loosening was observed in the PS implant (1 knee) and F-PS implant (2 knee). A prosthesis infection occurred in the CR implant. However, we did not exclude these four knees in the survival analysis. Of the remaining 179 knees (131 patients), CR implants were used in 45 knees (CR group), PS implants were used in 40 knees (PS group) and F-PS implants were used in 94 knees (F-PS group). The mean follow-up duration was 7.4 years (median, 7 years; range, 5 to 12 years). The CR, PS, and F-PS groups were followed-up for a mean of 8.1 years (range, 5 to 9.7 years), 8.0 years (range, 5 to 12 years) and 6.8 years (range, 5 to 8.8 years), respectively. Thirty six patients had bilateral total knee arthroplasties with the same prosthesis (6 patients with bilateral CR knees, 6 patients with bilateral PS knees and 24 patients with bilateral F-PS knees). Twelve patients underwent bilateral arthroplasty in which a different type of prosthesis was implanted in each knee (CR and PS, 3 patients; PS and F-PS, 2 patients; CR and F-PS, 7 patients).

All surgical procedures were performed by two experienced surgeons. Identical surgical techniques were used in the three groups, except for preservation of the PCL and larger posterior tibial slope in the CR group. An attempt was made to produce tibial slope of 6° in the CR knees, and 3° in the PS and F-PS knees. A medial parapatellar arthrotomy was used, and the patellae were routinely resurfaced. The patellae with normal cartilage or small patellae (less than or equal to 20 mm in thickness) were preserved. All prostheses were fixed with cement. The same rehabilitation protocol was applied to all groups in postoperation. Patients began knee flexion exercises using a continuous passive motion exercise machine on the first day after the surgery and were allowed to walk using a walker on the second day.

Clinical and radiographic evaluations were performed three months and one year after surgery and annually thereafter. However, postoperative knee scores have been regularly assessed since 2005. The active maximal knee-flexion angle and flexion contracture were measured using a goniometer with a patient in the supine position. Each knee was rated in accordance with the Knee Society and the Hospital for Special Surgery (HSS) scoring systems. In addition, each patient completed the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) health status questionnaire. The radiographic indices were measured on standard weight-bearing anteroposterior and long leg radiographs, supine lateral radiographs (30° flexed) and merchant radiographs. The tibiofemoral angle, posterior tibial slope, changes in the posterior condylar offset and joint line level were assessed. The joint line level was evaluated by the distance from the distal femoral condyle to the proximal fibular tip in the anteroposterior radiographs.

All statistical analyses were performed using two-tailed tests. A p-value of <0.05 was considered significant. The categorical variables were analyzed using a cross-tabulation with a chi-square. The continuous variables (i.e., age, body mass index [BMI], preoperative flexion angle, Knee Society scores) were examined with analysis of variance and Scheffe's post hoc test. An analysis of covariance was also performed to analyze the postoperative flexion angle with consideration of the preoperative flexion angle, age, BMI and preoperative tibiofemoral angle. The survival rate was estimated by Kaplan-Meier analysis using a revision for any reason as an end point. A log-rank test was used to test for the differences in the survival curve by an implant subtype.


Results

There was no significant difference between the three groups in terms of the demographics and preoperative measurements except for the follow-up duration (Table 1).

At the 2-year follow-up, the mean active maximal flexion angles in the CR, PS, and F-PS groups were 114°, 119°, and 122°, respectively. The maximal flexion was significantly lower in the CR group than the F-PS group (p=0.013). On the other hand, the differences in the maximal flexion angle between the three groups decreased with time. Eventually, there was no significant difference in the active maximal flexion at the last follow-up. After adjusting for age, BMI and preoperative tibiofemoral angle, the mean maximal flexion angles of the CR knees was also significantly lower than that of the F-PS knees at the 2-year follow-up (p<0.001), and no significant difference was observed at the last follow-up (Table 2).

The average postoperative Knee Society knee score, Knee Society function score, HSS score, and WOMAC scores for the pain, stiffness and function subscales were similar between the groups at the last follow-up (Table 3).

Postoperative tibiofemoral angles averaged 6° of valgus in the CR group, 6° of valgus in the PS group, and 5° of valgus in the F-PS group (p=0.376). The mean changes in the posterior femoral condylar offset were also similar between the three groups (CR, 1±1.9 mm; PS, 1±2.3 mm; F-PS, 1±2.2 mm; p=0.647). The mean posterior tibial slope of the CR group was higher than the other groups (CR, 6°±1.8°; PS, 4°±2.8°; F-PS, 4°±2.3°; p<0.001). The joint line levels were 15 mm in the CR group, 14 mm in the PS group and 16 mm in the F-PS group (p=0.201).

After a minimum follow-up of 5 years, two knees underwent revision surgery for aseptic loosening (CR, 1 knee; PS, 1 knee). Including the cases followed up for less than 5 years, aseptic loosening occurred in five knees (CR, 1 knees; PS, 2 knees; F-PS, 2 knees). Loosening only involved the tibial component, and the plates medially sank down in all cases. The mean time from TKA to revision for aseptic loosening was 3.2±2.15 years. One PS knee was revised for periprosthetic fracture. There was no prosthesis infection after 5-year follow-up. The overall survival rate at 7 years was 96.1%, and there was no significant difference in the survival curve between the three groups (CR, 95.9%; PS, 92.3%; F-PS, 97%; p=0.716) (Fig. 2).


Discussion

The role of the posterior cruciate ligament and the effect of the design modifications for high flexion are controversial subjects in TKA. This study compared the results of CR, PS, and F-PS prostheses with identical femoral component design.

In the current study, the CR group had a lower mean maximal flexion angle than the PS (Δ5°) or F-PS (Δ9°) group at the 2-year follow-up, even though there was only a significant difference between the CR and F-PS group. Many short-term studies also found that PS knees had significantly greater maximal flexion than CR knees4,17,18). Although several studies showed that CR and PS knees had a similar range of motion, these studies had the mean preoperative maximal flexion of the CR knees at 4° to 9° higher than the PS knees9,19,20).

In the present study, as the maximal flexion of the CR group increased, the difference in maximal flexion between the CR and F-PS groups decreased at the last follow-up. An increase in the maximal flexion at the mid-term follow-up was also observed in another CR study21), and a decrease in maximal flexion was observed in another PS study22). The change of flexion angle in the CR knee may be referable to a degeneration or failure of PCL. Victor et al.10) reported that the mean flexion angle of the CR and PS designs were similar at the midterm follow-up. In contrast, Harato et al.5) demonstrated significantly greater average knee flexion of the PS knees at 5 year follow-up. However, the difference in the mean flexion angle was only 3.3°.

In the current study, the mean flexion angle of the F-PS group was similar to that of the PS group. On the other hand, in the several randomized, controlled studies, high flexion PS designs have demonstrated an improved range of motion comparing to the conventional PS designs6,23,24). In these studies, the design modifications for high flexion were mainly in the posterior femoral condylar offset and cam/post engagement. Other high flexion designs, which were characterized by changes in the polyethylene insert geometry without an increase of femoral condylar offset, did not show a significantly higher flexion arc than the conventional PS designs in the prospective study15).

Bellemans et al.25,26) reported that the posterior femoral condylar offset and posterior tibial slope can affect the postoperative range of motion. In the current study, the femoral condylar offsets were similarly restored in the three groups, but the mean tibial slopes were significantly different. We intentionally attempted to make a smaller tibial slope in the PS and F-PS groups because an excessive slope in a PS knee can cause posterior flexion instability27). Bellemans et al.26) stated that increasing the tibial slope improved maximal flexion, with an average of 1.7° more flexion for every degree extra of the tibial slope. Therefore, the difference in maximal flexion between the CR and PS knees has the potential to be undervalued in the current study.

The survival rate in this study was 96.1% at 7 years, which is comparable to the other midterm studies using identical prostheses. Abbas and Gunn28) reported a 99.3% survival rate on 173 primary PS TKA at 8 years. Similarly, Borrione et al.29) reported a 95.2% survival rate at 6 years in the multicenter study. In contrast to Rand et al.30), who reported a significantly lower survival rate for PS designs compared to CR designs, the survival curve of the CR group in the current study was similar to those of the other groups.

This study had several limitations. First, this study included a small population and was potentially underpowered, given a small difference in the clinical outcomes. Second, only twelve patients, who had a different type of prosthesis in each knee, were not included but both knees of the forty eight patients with bilateral arthroplasties were enrolled. This might have obscured the analysis. However, the functional status was assessed separately for each knee, and the outcomes were analyzed with consideration for possible confounding factors, such as preoperative flexion angle, age, BMI and preoperative tibiofemoral angle. Third, the index arthroplasties were carried out over a six year period, and the mean follow-up duration varied across the groups. Because the implants were chronologically chosen in order of the prosthesis development and launching, the mean follow-up durations were different between the groups.


Conclusions

In the present study, the retaining or substituting PCL and the change of polyethylene insert geometry for high flexion did not make a difference to the midterm clinical outcomes of TKA with identical femoral geometry. Although the maximal flexion was lower in the CR knee than the F-PS knee at 2-year follow-up, the difference in the maximal flexion decreased at the last follow-up. After a minimum follow-up of five years, the three different types of TKAs with identical femoral geometry provided similar outcomes with regard to the range of motion, functional outcomes and survival rate.


Acknowledgements

We thank the Medical Research Collaborating Center of Seoul National University Hospital for the help with statistical analysis. This study was supported by a grant from the Innovative Research Institute for Cell Therapy, Republic of Korea (Grant no. A062260).


References
1. Padua R,Ceccarelli E,Bondi R,Campi A,Padua L. Range of motion correlates with patient perception of TKA outcomeClin Orthop Relat ResYear: 200746017417717414170
2. Argenson JN,Parratte S,Ashour A,Komistek RD,Scuderi GR. Patient-reported outcome correlates with knee function after a single-design mobile-bearing TKAClin Orthop Relat ResYear: 20084662669267618709432
3. Noble PC,Conditt MA,Cook KF,Mathis KB. The John Insall Award: Patient expectations affect satisfaction with total knee arthroplastyClin Orthop Relat ResYear: 2006452354316967035
4. Maruyama S,Yoshiya S,Matsui N,Kuroda R,Kurosaka M. Functional comparison of posterior cruciate-retaining versus posterior stabilized total knee arthroplastyJ ArthroplastyYear: 20041934935315067650
5. Harato K,Bourne RB,Victor J,Snyder M,Hart J,Ries MD. Midterm comparison of posterior cruciate-retaining versus-substituting total knee arthroplasty using the Genesis II prosthesis. A multicenter prospective randomized clinical trialKneeYear: 20081521722118325770
6. Weeden SH,Schmidt R. A randomized, prospective study of primary total knee components designed for increased flexionJ ArthroplastyYear: 20072234935217400089
7. Huang HT,Su JY,Wang GJ. The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-upJ ArthroplastyYear: 20052067467916310007
8. Nutton RW,van der Linden ML,Rowe PJ,Gaston P,Wade FA. A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion componentsJ Bone Joint Surg BrYear: 200890374218160497
9. Conditt MA,Noble PC,Bertolusso R,Woody J,Parsley BS. The PCL significantly affects the functional outcome of total knee arthroplastyJ ArthroplastyYear: 20041910711215457428
10. Victor J,Banks S,Bellemans J. Kinematics of posterior cruciate ligament-retaining and -substituting total knee arthroplasty: a prospective randomised outcome studyJ Bone Joint Surg BrYear: 20058764665515855366
11. Fantozzi S,Catani F,Ensini A,Leardini A,Giannini S. Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: in vivo fluoroscopic analysis during activities of daily livingJ Orthop ResYear: 2006242222222917019683
12. Klein GR,Parvizi J,Rapuri VR,Austin MS,Hozack WJ. The effect of tibial polyethylene insert design on range of motion: evaluation of in vivo knee kinematics by a computerized navigation system during total knee arthroplastyJ ArthroplastyYear: 20041998699115586334
13. Kim YH,Sohn KS,Kim JS. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized studyJ Bone Joint Surg AmYear: 2005871470147515995113
14. Choi WC,Lee S,Seong SC,Jung JH,Lee MC. Comparison between standard and high-flexion posterior-stabilized rotating-platform mobile-bearing total knee arthroplasties: a randomized controlled studyJ Bone Joint Surg AmYear: 2010922634264220952606
15. McCalden RW,MacDonald SJ,Bourne RB,Marr JT. A randomized controlled trial comparing "high-flex" vs "standard" posterior cruciate substituting polyethylene tibial inserts in total knee arthroplastyJ ArthroplastyYear: 200924333819447001
16. Choi CH,Koo MH,Park YW. Comparative study of the postoperative maximal flexion angle in PCL-substituting TKAs: conventional PS vs. high-flex PSJ Korean Orthop AssocYear: 200944581585
17. Hirsch HS,Lotke PA,Morrison LD. The posterior cruciate ligament in total knee surgery. Save, sacrifice, or substitute?Clin Orthop Relat ResYear: 199430964687994978
18. Yoshiya S,Matsui N,Komistek RD,Dennis DA,Mahfouz M,Kurosaka M. In vivo kinematic comparison of posterior cruciate-retaining and posterior stabilized total knee arthroplasties under passive and weight-bearing conditionsJ ArthroplastyYear: 20052077778316139716
19. Tanzer M,Smith K,Burnett S. Posterior-stabilized versus cruciate-retaining total knee arthroplasty: balancing the gapJ ArthroplastyYear: 20021781381912375237
20. Chaudhary R,Beaupre LA,Johnston DW. Knee range of motion during the first two years after use of posterior cruciate-stabilizing or posterior cruciate-retaining total knee prostheses. A randomized clinical trialJ Bone Joint Surg AmYear: 2008902579258619047702
21. Bertin KC. Cruciate-retaining total knee arthroplasty at 5 to 7 years followupClin Orthop Relat ResYear: 200543617718315995438
22. Nerhus TK,Heir S,Thornes E,Madsen JE,Ekeland A. Time-dependent improvement in functional outcome following LCS rotating platform knee replacementActa OrthopYear: 20108172773221067429
23. Bin SI,Nam TS. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgeryKnee Surg Sports Traumatol ArthroscYear: 20071535035517072657
24. Seng C,Yeo SJ,Wee JL,Subanesh S,Chong HC,Lo NN. Improved clinical outcomes after high-flexion total knee arthroplasty: a 5-year follow-up studyJ ArthroplastyYear: 2011261025103021074355
25. Bellemans J,Banks S,Victor J,Vandenneucker H,Moemans A. Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offsetJ Bone Joint Surg BrYear: 200284505311837832
26. Bellemans J,Robijns F,Duerinckx J,Banks S,Vandenneucker H. The influence of tibial slope on maximal flexion after total knee arthroplastyKnee Surg Sports Traumatol ArthroscYear: 20051319319615824934
27. Sierra RJ,Berry DJ. Surgical technique differences between posterior-substituting and cruciate-retaining total knee arthroplastyJ ArthroplastyYear: 200823202318701240
28. Abbas D,Gunn RS. Medium-term results of the Scorpio total knee replacementKneeYear: 20061330731116806941
29. Borrione F,Bonnevialle P,Mabit C,Guingand O,Bertin D,Bonnomet F,Denis C,Gagna G. Scorpio single radius total knee arthroplasty. A minimal five-year follow-up multicentric studyInt OrthopYear: 2011351777178221365193
30. Rand JA,Trousdale RT,Ilstrup DM,Harmsen WS. Factors affecting the durability of primary total knee prosthesesJ Bone Joint Surg AmYear: 20038525926512571303

Article Categories:
  • Original Article

Keywords: Knee, Total knee arthroplasty, Posterior cruciate-retaining, Posterior cruciate-substituting, High-flex implant.

Previous Document:  Results of Total Knee Arthroplasty with NexGen LPS-flex Implant Using Navigation System (Brain Lab):...