Oropharyngeal leak pressure with the laryngeal mask airway Supreme™ at different intracuff pressures: a randomized controlled trial.
MedLine Citation:
PMID:  21533663     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
BACKGROUND: A higher oropharyngeal leak pressure (OLP) is a marker of efficacy and safety when using laryngeal mask airway devices. The new disposable laryngeal mask airway (LMA™) Supreme™ has lower OLP compared with the LMA ProSeal™. Increased intracuff pressure of laryngeal mask airway devices may improve OLP but may result in more postoperative pharyngolaryngeal adverse events. This study was designed to compare the OLP of the LMA Supreme at varying intracuff pressures. METHODS: One hundred and twenty-three patients were divided randomly into three groups. General anesthesia was standardized using a propofol-fentanyl induction and desflurane in air-oxygen for maintenance. Intracuff pressures of the LMA Supreme were adjusted to 80 cm H(2)O, 60 cm H(2)O, and 40 cm H(2)O according to group allocation. The primary outcome was OLP. Secondary outcomes included postoperative pharyngolaryngeal adverse events and the satisfaction scores of patients and anesthesiologists. The OLP was compared amongst groups using analysis of variance with Bonferroni correction. All reported P values are two-sided. RESULTS: The OLP with an intracuff pressure of 80 cm H(2)O was significantly higher compared with 60 cm H(2)O and 40 cm H(2)O (26 [6] vs 20 [6] vs 18 [5] cm H(2)O, respectively; P < 0.001). The incidence of postoperative pharyngolaryngeal adverse events (P = 0.6), patient satisfaction scores (P = 0.2), and anesthesiologist satisfaction scores (P = 0.8) were comparable amongst the three groups. CONCLUSION: An intracuff pressure of 80 cm H(2)O with the LMA Supreme is associated with a higher OLP compared with 60 cm H(2)O or 40 cm H(2)O without a greater incidence of postoperative pharyngolaryngeal adverse events. For a superior glottic seal when using the LMA Supreme, we recommend intracuff pressures up to 80 cm H(2)O.
Authors:
Lianfeng Zhang; Edwin Seet; Vanita Mehta; Rajeev Subramanyam; Saravanan P Ankichetty; David T Wong; Frances Chung
Related Documents :
8846033 - The abdominal lift: is there any advantage for the critically ill patient?
3135953 - Effects of caudal block with mepivacaine on resting ventilation and ventilatory respons...
17818433 - Mineral-produced high-pressure striae and clay polish: key evidence for nonballistic tr...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2011-4-30
Journal Detail:
Title:  Canadian journal of anaesthesia = Journal canadien d'anesthesie     Volume:  -     ISSN:  1496-8975     ISO Abbreviation:  -     Publication Date:  2011 Apr 
Date Detail:
Created Date:  2011-5-2     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8701709     Medline TA:  Can J Anaesth     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
Department of Anesthesia, University Health Network, University of Toronto, 399 Bathurst St., McL 2-405, Toronto, ON, M5T 2S8, Canadaa.
Vernacular Title:
La pression de fuite oropharyngienne avec le masque laryngé Supreme™ à différentes pressions intra-ballonnet: une étude randomisée contrôlée.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Autologous Cell-Enriched Fat Grafting for Breast Augmentation.
Next Document:  Empirical Study of an Adaptive Multiscale Model for Simulating Cardiac Conduction.