Optimized venous return with a self-expanding cannula: from computational fluid dynamics to clinical application.
MedLine Citation:
PMID:  17669950     Owner:  NLM     Status:  PubMed-not-MEDLINE    
Abstract/OtherAbstract:
The Smart canula concept allows for collapsed cannula insertion, and self-expansion within a vein of the body. (A) Computational fluid dynamics, and (B) bovine experiments (76+/-3.8 kg) were performed for comparative analyses, prior to (C) the first clinical application. For an 18F access, a given flow of 4 l/min (A) resulted in a pressure drop of 49 mmHg for smart cannula versus 140 mmHg for control. The corresponding Reynolds numbers are 680 versus 1170, respectively. (B) For an access of 28F, the maximal flow for smart cannula was 5.8+/-0.5 l/min versus 4.0+/-0.1 l/min for standard (P<0.0001), for 24F 5.5+/-0.6 l/min versus 3.2+/-0.4 l/min (P<0.0001), and for 20F 4.1+/-0.3 l/min versus 1.6+/-0.3 l/min (P<0.0001). The flow obtained with the smart cannula was 270+/-45% (20F), 172+/-26% (24F), and 134+/-13% (28F) of standard (one-way ANOVA, P=0.014). (C) First clinical application (1.42 m2) with a smart cannula showed 3.55 l/min (100% predicted) without additional fluids. All three assessment steps confirm the superior performance of the smart cannula design.
Authors:
Xavier M Mueller; Iker Mallabiabrena; Giuseppe Mucciolo; Ludwig K von Segesser
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Interactive cardiovascular and thoracic surgery     Volume:  1     ISSN:  1569-9285     ISO Abbreviation:  Interact Cardiovasc Thorac Surg     Publication Date:  2002 Sep 
Date Detail:
Created Date:  2007-08-02     Completed Date:  2007-08-07     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  101158399     Medline TA:  Interact Cardiovasc Thorac Surg     Country:  England    
Other Details:
Languages:  eng     Pagination:  23-7     Citation Subset:  -    
Affiliation:
Department of Cardio-Vascular Surgery, Centre Hospitalier Universitaire Vaudois (CHUV), Rue du Bugnon 46, CH-1011 Lausanne, Switzerland.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Endothelial function after prolonged coronary artery oxygen persufflation in a rabbit model of heart...
Next Document:  How to determine the correct placement of the retrograde cardioplegia catheter.