Document Detail


Optimal trocar placement for ergonomic intracorporeal sewing and knotting in laparoscopic hiatal surgery.
MedLine Citation:
PMID:  20638045     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
BACKGROUND: Trocar placement presently is mostly empiric. Our goal was to define simple distances from bony landmarks to locate the optimal ergonomic placement of manipulation trocars for access to the lower esophagus and hiatal orifice, for suture placement, and knotting of the gastric fundus and crura. Hypothesizing that the ideal ergonomic principles of a manipulation angle of 60°, an elevation angle (α(e)) of 30° to 60°, and an intracorporeal/extracorporeal length ratio (I/E) of working instruments close to 1:1 are interrelated by simple trigonometric functions, the variations of each of these parameters were calculated in a dependent manner for 2 standard lengths of needle holders: 48.5 cm and 58.5 cm. RESULTS: Trocar placement can be calculated easily according to simple formulas dependent on the α(e), the distance from the sternoxiphoid junction to the median of the intertrocar span (d) and the vertical distance from the stenoxiphoid junction to the average distance between the apex of the hiatal orifice and the anterior aspect of the esophagus (XH'): when the α(e) is 30°: d is XH' √2 and when α(e) is 45°, d is XH'/√2. Likewise, when α(e) is 30° the intertrocar span (LR) is 2XH', half on either side of the optical axis (d), and when α(e) is 45°, LR is XH' √2, XH'/√2 on either side of the optical axis. The most ergonomic solution is to work with an α(e) of 40° to 45° by placing the 2 working (manipulation) trocars, between 10 and 14 cm caudad from the sternoxiphoid junction, between 10 and 12 cm on either side of the longitudinal axis corresponding to the optic-target axis. The shorter needle holder works best in this configuration because the I/E ratio will be between .8 and 1. If, however, the surgeon wants to work with an α(e) closer to 30°, then the longer needle holder should be used, and the trocars should be placed between 20 and 21 cm from the sternoxiphoid junction, 14.5 to 15 cm on either side of the optical axis. The I/E ratio will vary between 1 and 1.1. When a 1/1 I/E ratio was prioritized, the α(e) would be 40° and 32°, for the shorter and longer instruments, respectively. The deeper crural closure requires increasing the α(e) by 2° and 3°, respectively. Hyperlordosis, as obtained by placing a cushion under the patient's back, shortens the distances, allowing placement of the trocars closer to the sternoxiphoid junction. CONCLUSIONS: Based on ergonomic principles (manipulation angle, 60°; α(e), 40°-45°; and an I/E ratio of working instruments, close to 1:1), simple trigonometric considerations allow easy calculation of the ideal placement of trocars corresponding to working instruments in hiatal surgery necessary for ergonomic dissection, suturing, and intracorporeal knotting. Ideal trocar placement is dependent only on the vertical depth of the target organ.
Authors:
Abe Fingerhut; George B Hanna; Nicolas Veyrie; George Ferzli; Bertrand Millat; Nicholas Alexakis; Emmanuel Leandros
Related Documents :
7622625 - Rabbit skeletal muscle alpha alpha-tropomyosin expressed in baculovirus-infected insect...
153745 - Isolation and properties of brain alpha-actinin.
6782195 - Highly sensitive immunoassays for three forms of rat brain enolase.
20580015 - Preparation of microspherical alpha-zirconium phosphate catalysts for conversion of fat...
11083815 - Interleukin-1 receptor type i gene-deficient mice are less susceptible to staphylococcu...
15949035 - Overexpression of extracellular superoxide dismutase reduces acute radiation induced lu...
Publication Detail:
Type:  Comparative Study; Journal Article     Date:  2010-07-16
Journal Detail:
Title:  American journal of surgery     Volume:  200     ISSN:  1879-1883     ISO Abbreviation:  Am. J. Surg.     Publication Date:  2010 Oct 
Date Detail:
Created Date:  2010-10-04     Completed Date:  2010-10-21     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  0370473     Medline TA:  Am J Surg     Country:  United States    
Other Details:
Languages:  eng     Pagination:  519-28     Citation Subset:  AIM; IM    
Copyright Information:
Copyright © 2010 Elsevier Inc. All rights reserved.
Affiliation:
First Department of Surgery, Hippocration Hospital, University of Athens Medical School, Athens, Greece.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Equipment Design
Hernia, Hiatal / surgery*
Human Engineering / methods*
Humans
Laparoscopes*
Laparoscopy / methods*
Reproducibility of Results
Suture Techniques / instrumentation*
Sutures*
Thorax / anatomy & histology*

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine