Document Detail


Optimal radiofrequency and gradient spoiling for improved accuracy of T1 and B1 measurements using fast steady-state techniques.
MedLine Citation:
PMID:  20512865     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Variable flip angle T(1) mapping and actual flip-angle imaging B(1) mapping are widely used quantitative MRI methods employing radiofrequency spoiled gradient-echo pulse sequences. Incomplete elimination of the transverse magnetization in these sequences has been found to be a critical source of T(1) and B(1) measurement errors. In this study, comprehensive theoretical analysis of spoiling-related errors in variable flip angle and actual flip-angle imaging methods was performed using the combined isochromat summation and diffusion propagator model and validated by phantom experiments. The key theoretical conclusion is that correct interpretation of spoiling phenomena in fast gradient-echo sequences requires accurate consideration of the diffusion effect. A general strategy for improvement of T(1) and B(1) measurement accuracy was proposed based on the strong spoiling regimen, where diffusion-modulated spatial averaging of isochromats becomes a dominant factor determining magnetization evolution. Practical implementation of strongly spoiled variable flip angle and actual flip-angle imaging techniques requires sufficiently large spoiling gradient areas (A(G)) in combination with optimal radiofrequency phase increments (phi(0)). Optimal regimens providing <2% relative T(1) and B(1) measurement errors in a variety of tissues were theoretically derived for prospective in vivo variable flip angle (pulse repetition time = 15-20 ms, A(G) = 280-450 mT.ms/m, phi(0) = 169 degrees) and actual flip-angle imaging (pulse repetition time(1)/pulse repetition time(2) = 20/100 ms, A(G1)/A(G2) = 450/2250 mT.ms/m, phi(0) = 39 degrees) applications based on 25 mT/m maximal available gradient strength.
Authors:
Vasily L Yarnykh
Related Documents :
3367775 - An analysis of fast imaging sequences with steady-state transverse magnetization refocu...
3185135 - The application of steady-state free precession in rapid 2dft nmr imaging: fast and ce-...
8237705 - Fast spin-echo mr imaging of the cervical spine: influence of echo train length and ech...
8057765 - Acquisition of spin echo and stimulated echo by a single sequence: application to mri o...
20038905 - Diagnostic of craniofacial asymmetry. literature review.
18285175 - Fuzzy stack filters-their definitions, fundamental properties, and application in image...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine / Society of Magnetic Resonance in Medicine     Volume:  63     ISSN:  1522-2594     ISO Abbreviation:  Magn Reson Med     Publication Date:  2010 Jun 
Date Detail:
Created Date:  2010-05-31     Completed Date:  2010-09-23     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8505245     Medline TA:  Magn Reson Med     Country:  United States    
Other Details:
Languages:  eng     Pagination:  1610-26     Citation Subset:  IM    
Copyright Information:
(c) 2010 Wiley-Liss, Inc.
Affiliation:
Bio-Molecular Imaging Center, Department of Radiology, University of Washington, Seattle, Washington 98109, USA. yarnykh@u.washington.edu
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Echo-Planar Imaging
Image Enhancement
Magnetic Resonance Imaging*
Models, Biological*
Phantoms, Imaging
Radio Waves*
Reproducibility of Results
Time Factors

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Comparison of quantitative parameters in cervix cancer measured by dynamic contrast-enhanced MRI and...
Next Document:  Multislice perfusion of the kidneys using parallel imaging: Image acquisition and analysis strategie...