PURPOSE: To evaluate the optical quality of the Visian Implantable Collamer Lens (ICL) for different powers and pupil diameters. METHODS: Wavefront aberrations of the -3, -6, -9, -12 and -15 diopters (D) V4b ICLs were measured at 3- and 4.5-mm pupils. The root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration were evaluated. In addition, modulation transfer function (MTF) of the five ICL powers was measured for a 3-mm pupil. The point spread functions (PSFs) of each ICL evaluated was calculated from the wavefront aberrations at 4.5-mm pupil. RESULTS: The ICLs evaluated had negative spherical aberration and negligible amounts of other aberrations. The negative spherical aberration increases when the ICL power increases being related with its innate optical properties. At 3-mm pupil, no statistically significant differences between ICLs were found for all the Zernike coefficient RMS values analyzed (p > 0.05). At 4.5-mm pupil, significant RMS values for the spherical aberration and total HOAs were found between medium-low and high powers (p < 0.05). Similar MTFs were obtained for all ICLs, although they slightly worsened when increased the ICL power. CONCLUSIONS: ICLs evaluated provide good optical quality in terms of wavefront aberrations, MTF, and PSF. Although spherical aberration increases with ICL power, these values are clinically negligible to affect the visual quality after its implantation.
Authors:
Cari Pérez-Vives; Alberto Domínguez-Vicent; Teresa Ferrer-Blasco; Alvaro M Pons; Robert Montés-Micó
Related Documents :
22316174 - Safety evaluation of 32p-chromic phosphate-poly l lactic acid particles interstitially ...
22912524 - Functional and oncologic outcomes after excision of the total femur in primary bone tum...
3755214 - Improved "nonisolated-sensor" solid polystyrene calorimeter.
23748304 - Osseointegration of implants in irradiated bone with and without hyperbaric oxygen trea...
2199124 - Prostaglandin e2 levels in the membrane surrounding bulk and particulate polymethylmeth...
16850464 - Influence of implant surface topography on early osseointegration: a histological study...
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2012-11-11
Journal Detail:
Title:  Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie     Volume:  -     ISSN:  1435-702X     ISO Abbreviation:  Graefes Arch. Clin. Exp. Ophthalmol.     Publication Date:  2012 Nov 
Date Detail:
Created Date:  2012-11-12     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  8205248     Medline TA:  Graefes Arch Clin Exp Ophthalmol     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Affiliation:
GIO, Optics Department, Faculty of Physics, Universidad de Valencia, Valencia, Spain, cari.perez@uv.es.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Anterior chamber paracentesis and pH values in patients with acute primary angle closure.
Next Document:  Early neurogenesis during caudal spinal cord regeneration in adult Gekko japonicus.