BACKGROUND: Edge dissections after coronary stent implantation are associated with increased short-term risk of major adverse cardiovascular events. The incidence and outcome of edge dissections after coronary stent implantation were reportedly different using different imaging techniques. We used optical coherence tomography (OCT) to assess the incidence, morphological findings and related factors of edge dissections after drug-eluting stent (DES) implantation.
METHODS: Totally 42 patients with 43 de novo lesions in 43 native arteries undergoing DES implantation with OCT imaging were enrolled in this study.
RESULTS: Nine edge dissections were detected in 43 arteries after DES implantation. There were four morphological patterns of stent edge dissections indentified in this study: (1) superficial intimal tears (n = 3), (2) subintimal dissections (n = 4), (3) split of media (n = 1), (4) disruption of the fibrotic cap of plaque (n = 1). Stent edge expansion and stent expansion were both higher in the group with dissections than those in the group without dissections (1.682 ± 0.425 vs. 1.229 ± 0.285, P = 0.0290; 1.507 ± 0.445 vs. 1.174 ± 0.265, P = 0.0072).
CONCLUSIONS: The incidence of stent edge dissections detected by OCT was 21%. Stent edge dissection is related with stent edge expansion and stent expansion.
Authors:
Jun Guo; Yun-Dai Chen; Feng Tian; Hong-Bin Liu; Lian Chen; Zhi-Jun Sun; Yi-Hong Ren; Qin-Hua Jin; Chang-Fu Liu; Bao-Shi Han; Lu-Yue Gai; Ting-Shu Yang
Related Documents :
12483009 - Parallel technique of endobronchial balloon catheter tamponade for transient alleviatio...
961039 - Complications encountered during arterial embolectomy with the fogarty balloon catheter.
22919139 - Hepatorenal bypass using autogenous, free internal iliac artery graft: an attractive al...
22737829 - Spontaneous hemothorax: first manifestation of pulmonary arteriovenous malformation in ...
10147759 - A pulmonary artery catheter does not affect the intravascular electrocardiogram from th...
16843319 - Occlusion of silastic broviac catheters as a result of twisting between the catheter an...
10614099 - Surgical treatment of tricuspid regurgitation caused by löffler's endocarditis.
1837949 - Vocal cord dysfunction presenting as bronchial asthma: the association with abnormal th...
14571479 - Simultaneous stenting of the carotid artery and other coronary or extracoronary arterie...
Publication Detail:
Type:  Journal Article    
Journal Detail:
Title:  Chinese medical journal     Volume:  125     ISSN:  0366-6999     ISO Abbreviation:  Chin. Med. J.     Publication Date:  2012 Mar 
Date Detail:
Created Date:  2012-05-22     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7513795     Medline TA:  Chin Med J (Engl)     Country:  China    
Other Details:
Languages:  eng     Pagination:  1047-50     Citation Subset:  IM    
Affiliation:
Department of Cardiology, Chinese People's Liberation Army General Hospital, Beijing 100853, China.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Impact of weight gain following smoking cessation on one-year outcome after drug-eluting stent impla...
Next Document:  Plasma neutrophil-gelatinase-associated lipocalin and cystatin C could early diagnose contrast-induc...