Document Detail


One Poke or Two: Can Intravenous Catheters Provide an Acceptable Blood Sample? A Data Set Presentation, Review of Previous Data Sets, and Discussion.
MedLine Citation:
PMID:  23333158     Owner:  NLM     Status:  Publisher    
Abstract/OtherAbstract:
The purpose of this study was to show that acceptable blood samples can be collected through intravenous (IV) catheters. Hemolysis of blood samples and appropriate methods of blood sample collection can be a topic of controversy in an emergency department and throughout a hospital. This investigation was conducted by laboratory personnel and ED nursing staff at a moderately sized hospital in the northwestern United States. Nearly 9,000 blood draws were collected and categorized between May and August 2011 to determine hemolysis rates. At the start of this project, there was some question about whether blood collected from IV catheter starts in the emergency department provided an acceptable laboratory sample. By the end of the project, it was clear that low rates of hemolysis were consistently achievable by each of the 3 methods investigated. METHODS: Information was collected electronically as part of the standard laboratory intake and processing of samples. The level of hemolysis in a blood sample was measured spectrophotometrically by automated laboratory equipment as part of the sample intake process. The data were then cataloged and presented monthly. Because of the simplicity of this project and the clarity of the results, only simple summary statistics were performed to assist in interpretation of the data. RESULTS: The rates of blood samples rejected because of hemolysis were as follows: 1.1% when collected from an IV catheter start, 0.8% when collected from an existing vascular access, and 0.1% when collected by venipuncture with a steel needle. DISCUSSION: The data show that low rates of samples rejected because of hemolysis are achievable by the collection of blood from an IV catheter start. With all 3 collection methods studied, the sample rejection rates because of hemolysis were well below the 2% level that has been cited as a benchmark best practice of the American Society of Clinical Pathology. The results of this investigation clearly support the use of blood samples collected from IV starts.
Authors:
Henry Dietrich
Related Documents :
22936688 - In vitro comparison of two different methods of cell washing.
16049908 - Combining spect medical imaging and computational fluid dynamics for analyzing blood an...
9736788 - Is post-dialysis urea rebound significant with long slow hemodialysis?
24615248 - Flow metering characterization within an electrical cell counting microfluidic device.
1280598 - Glibenclamide and l-ng-nitro-arginine methyl ester modulate the ocular and hypotensive ...
11108878 - The levonorgestrel intrauterine system in contraception.
Publication Detail:
Type:  JOURNAL ARTICLE     Date:  2013-1-17
Journal Detail:
Title:  Journal of emergency nursing: JEN : official publication of the Emergency Department Nurses Association     Volume:  -     ISSN:  1527-2966     ISO Abbreviation:  J Emerg Nurs     Publication Date:  2013 Jan 
Date Detail:
Created Date:  2013-1-21     Completed Date:  -     Revised Date:  -    
Medline Journal Info:
Nlm Unique ID:  7605913     Medline TA:  J Emerg Nurs     Country:  -    
Other Details:
Languages:  ENG     Pagination:  -     Citation Subset:  -    
Copyright Information:
Copyright © 2013 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved. Published by Mosby, Inc. All rights reserved.
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Cue-induced conditioned activity does not incubate but is mediated by the basolateral amygdala.
Next Document:  Adrenalectomy and corticosterone replacement differentially alter CA3 dendritic morphology and new c...