Document Detail


Off-line exhaled nitric oxide measurements in children.
MedLine Citation:
PMID:  11477733     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
The concentration of exhaled nitric oxide (eNO) is a useful marker of asthmatic bronchial inflammation. eNO can now be measured away from the laboratory (off-line), even in children. Short exhalation maneuvers (8 sec) and small samples (1 L) of exhaled gas are probably sufficient in children, but more information is needed about the effect of different measurement conditions. As a preliminary step before conducting epidemiological studies in schoolchildren, we investigated the effects of expiratory flow, dead space, and expiratory time on eNO concentrations collected in 1-L mylar collection bags. We studied 101 cooperative subjects (62 males) aged 5-18 years (30 healthy volunteers, 51 asthmatics, and 20 children with various other respiratory diseases) in our pulmonary function laboratory. On-line and off-line eNO were compared in a single session, and analyzed with a Sievers NOA 280 nitric oxide analyzer. For both methods of collecting expired gas, subjects did a single exhalation without breath-holding against an expiratory pressure 10 cm H(2)O. We investigated the effects of expiratory flow, dead space, and exhalation time on eNO; we also compared on-line and off-line eNO measurements, and the repeatability of both techniques at a given flow rate. Expiratory flows of 58 mL/sec provided more reproducible data than lower flows (coefficient of repeatability 1.1 ppb for 58 mL/sec vs. 2.8 for 27 mL/sec vs. 5.7 for 18 mL/sec). eNO concentrations were about 25% higher in off-line than in on-line recordings if the initial 250 mL of exhaled gas were not eliminated, and 37% higher if exhalation lasted longer (16 sec vs. 8 sec). Eliminating 250 mL of dead space and shortening the filling time to 8 sec yielded off-line eNO values close to those on-line (geometric mean off-line eNO 14.4 ppb, 95% confidence interval: 12.2-17.0) vs. on-line eNO 13.8 ppb (95% confidence interval: 11.6-16.5). On-line and off-line results were highly correlated (r = 0.996, P = 0.000) and had similar coefficients of variation (on-line eNO 2.6%, off-line 2.8%). Neither agreement nor repeatability of eNO measurements were affected by disease status or baseline FEV(1) (% predicted values). Once standardized, the off-line eNO technique using 1-L gas collection bags will provide results similar to those recorded on-line.
Authors:
M Barreto; M P Villa; S Martella; C Falasca; F Guglielmi; J Pagani; M T Darder; R Ronchetti
Related Documents :
19740263 - Resistance and reactance in oscillation lung function reflect basal lung function and b...
20497363 - Consistently high levels of exhaled nitric oxide in children with asthma.
17683103 - The alcohol-aggression link: children's aggression expectancies in marital arguments as...
Publication Detail:
Type:  Evaluation Studies; Journal Article    
Journal Detail:
Title:  Pediatric pulmonology     Volume:  32     ISSN:  8755-6863     ISO Abbreviation:  Pediatr. Pulmonol.     Publication Date:  2001 Aug 
Date Detail:
Created Date:  2001-07-30     Completed Date:  2001-09-20     Revised Date:  2006-03-28    
Medline Journal Info:
Nlm Unique ID:  8510590     Medline TA:  Pediatr Pulmonol     Country:  United States    
Other Details:
Languages:  eng     Pagination:  159-67     Citation Subset:  IM    
Copyright Information:
Copyright 2001 Wiley-Liss, Inc.
Affiliation:
II Pediatric Department, University "La Sapienza," Rome, Italy. barreto@katamail.com
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Adolescent
Asthma / diagnosis*
Automation
Biological Markers / analysis*
Breath Tests / methods
Child
Child, Preschool
Epidemiologic Studies
Female
Humans
Inflammation
Male
Nitric Oxide / analysis*
Reference Values
Respiration
Specimen Handling
Chemical
Reg. No./Substance:
0/Biological Markers; 10102-43-9/Nitric Oxide

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Sputum processing for evaluation of inflammatory mediators.
Next Document:  Efficacy of early piston-type high-frequency oscillatory ventilation in infants with respiratory dis...