Document Detail


Numerical study on the pulsatile flow characteristics of proximal anastomotic models.
MedLine Citation:
PMID:  16225153     Owner:  NLM     Status:  MEDLINE    
Abstract/OtherAbstract:
Haemodynamics was widely believed to correlate with anastomosis restenosis. Utilizing the haemodynamic parameters as indicator functions, distal anastomosis was redesigned by some researchers so as to improve the long-term graft patency rate. However, there were few studies upon the proximal anastomosis. Therefore, in this study, flow characteristics and distributions of the haemodynamic parameters in proximal anastomosis under physiological flow condition have been investigated numerically for three different grafting angles: namely, 45 degrees forward facing, 45 degrees backward facing, and 90 degrees anastomotic joints. The simulation results showed a flow separation region along the graft inner wall immediately after the heel at peak flow phase and it decreased in size with the grafting angle shifting from 45 degrees forward facing to 45 degrees backward facing. At the same time, a pair of vortex was found in the cross-sectional planes of the 45 degrees backward facing and 90 degrees grafts. In addition, stagnation point was found along the graft outer wall with small shifting during the physiological cycle. High spatial and temporal wall shear stresses gradients (WSSG) were observed around the anastomotic joint. Low time-averaged wall shear stress (WSS) with elevated oscillation shear index (OSI) was found near the middle of anastomosis at the aorta wall and along the graft inner wall respectively, while high time-averaged WSS with low OSI was found at the heel, the toe, and the region downstream of the toe. These regions correlated to early lesion growth. Elevated time-averaged WSSG was found at the same region, where the elevated low-density lipoprotein (LDL) permeability was observed as reported in the literature. The existence of nearly fixed stagnating location, flow separation, vortex, high time-averaged WSS with low OSI, low time-averaged WSS with elevated OSI, and high time-averaged WSSG may lead to graft stenosis. Moreover, the simulation results obtained were consistent with those of experimental measurements. Based on the validated simulation results, the 45 degrees backward-facing graft was found to have the lowest variation range of time-averaged WSS and the lowest segmental average of WSSG among the three models investigated. The 45 degrees backward-facing graft is thus recommended for the bypass operation with expected higher patency rate.
Authors:
L P Chua; J-M Zhang; S C M Yu; D N Ghista; Y S Tan
Related Documents :
14500073 - Dopexamine increases internal mammary artery blood flow following coronary artery bypas...
12623333 - Interobserver variation in duplex scanning of infrainguinal arterial bypass grafts.
4073533 - The fetal vascularisation of term human placental villi. i. peripheral stem villi.
Publication Detail:
Type:  Journal Article; Research Support, Non-U.S. Gov't    
Journal Detail:
Title:  Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine     Volume:  219     ISSN:  0954-4119     ISO Abbreviation:  Proc Inst Mech Eng H     Publication Date:  2005 Sep 
Date Detail:
Created Date:  2005-10-17     Completed Date:  2005-11-07     Revised Date:  2009-06-08    
Medline Journal Info:
Nlm Unique ID:  8908934     Medline TA:  Proc Inst Mech Eng H     Country:  England    
Other Details:
Languages:  eng     Pagination:  361-79     Citation Subset:  IM    
Affiliation:
Thermal and Fluids Engineering Division, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore. mlpchua@ntu.edu.sg
Export Citation:
APA/MLA Format     Download EndNote     Download BibTex
MeSH Terms
Descriptor/Qualifier:
Anastomosis, Surgical*
Arteriovenous Anastomosis / physiopathology*
Blood Flow Velocity*
Blood Pressure*
Computer Simulation
Humans
Models, Cardiovascular*
Numerical Analysis, Computer-Assisted
Pulsatile Flow*
Shear Strength

From MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine


Previous Document:  Wire tension in the Ilizarov system: accuracy of the wire-tensioning device.
Next Document:  Injection-moulded models of major and minor arteries: the variability of model wall thickness owing ...